arrow
返回

Iterative regularization in intensity-modulated radiation therapy optimization

delete2005-12-28
delete18
PRE
AI
F
Fredrik Carlsson *
A
Anders Forsgren
DOI:10.1118/1.2148918delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
A common way to solve intensity-modulated radiation therapy (IMRT) optimization problems is to use a beamlet-based approach. The approach is usually employed in a three-step manner: first a beamlet-weight optimization problem is solved, then the fluence profiles are converted into stepand-shoot segments, and finally postoptimization of the segment weights is performed. A drawback of beamlet-based approaches is that beamlet-weight optimization problems are ill-conditioned and have to be regularized in order to produce smooth fluence profiles that are suitable for conversion. The purpose of this paper is twofold: first, to explain the suitability of solving beamlet-based IMRT problems by a BFGS quasi-Newton sequential quadratic programming method with diagonal initial Hessian estimate, and second, to empirically show that beamlet-weight optimization problems should be solved in relatively few iterations when using this optimization method. The explanation of the suitability is based on viewing the optimization method as an iterative regularization method. In iterative regularization, the optimization problem is solved approximately by iterating long enough to obtain a solution close to the optimal one, but terminating before too much noise occurs. Iterative regularization requires an optimization method that initially proceeds in smooth directions and makes rapid initial progress. Solving ten beamlet-based IMRT problems with dose-volume objectives and bounds on the beamlet-weights, we find that the considered optimization method fulfills the requirements for performing iterative regularization. After segment-weight optimization, the treatments obtained using 35 beamlet-weight iterations outperform the treatments obtained using 100 beamlet-weight iterations, both in terms of objective value and of target uniformity. We conclude that iterating too long may in fact deteriorate the quality of the deliverable plan. (c) 2006 American Association of Physicists in Medicine.
Keyword:
intensity-modulated radiation therapy
quasi-Newton method
conjugate gradient method
regularization
iterative regularization

期刊

Medical Physics 封面图
Medical Physics
IF:
3.2
论文数:
3.7W
被引数:
3.2W

机构

暂无机构信息
引用论文

引用论文

Regularization of inverse planning for intensity-modulated radiotherapy
err2005-01-27
err14
PREAI
errChvetsov, AV; Calvetti, D; Sohn, JW; Kinsella, TJ
err分享
err收藏
Improving IMRT delivery efficiency using intensity limits during inverse planning
err2005-04-12
err55
errOAAI
errCoselmon, MM; Moran, JM; Radawski, JD; Fraass, BA
err分享
err收藏
err分享
err收藏
学者 查看更多内容