arrow
返回

Joint Center Estimation Using Single-Frame Optimization: Part 2: Experimentation

delete2018-08-05
delete5
delete
OA
AI
E
Eric Frick
S
Salam Rahmatalla *
DOI:10.3390/s18082563delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Human motion capture is driven by joint center location estimates, and error in their estimation can be compounded by subsequent kinematic calculations. Soft tissue artifact (STA), the motion of tissue relative to the underlying bones, is a primary cause of error in joint center calculations. A method for mitigating the effects of STA, single-frame optimization (SFO), was introduced and numerically verified in Part 1 of this work, and the purpose of this article (Part 2) is to experimentally compare the results of SFO with a marker-based solution. The experimentation herein employed a single-degree-of-freedom pendulum to simulate human joint motion, and the effects of STA were simulated by affixing the inertial measurement unit to the pendulum indirectly through raw, vacuum-sealed meat. The inertial sensor was outfitted with an optical marker adapter so that its location could be optically determined by a camera-based motion-capture system. During the motion, inertial effects and non-rigid attachment of the inertial sensor caused the simulated STA to manifest via unrestricted motion (six degrees of freedom) relative to the rigid pendulum. The redundant inertial and optical instrumentation allowed a time-varying joint center solution to be determined both by optical markers and by SFO, allowing for comparison. The experimental results suggest that SFO can achieve accuracy comparable to that of state-of-the-art joint center determination methods that use optical skin markers (root mean square error of 7.87-37.86 mm), and that the time variances of the SFO solutions are correlated (r = 0.58-0.99) with the true, time-varying joint center solutions. This suggests that SFO could potentially help to fill a gap in the existing literature by improving the characterization and mitigation of STA in human motion capture.
Keyword:
motion capture
inertial sensors
optical markers
joint center
soft tissue artifact
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Sensors 封面图
Sensors
IF:
3.5
论文数:
7.2W
被引数:
20.9W

机构

U
University of Iowa
学者数:
2.8W
论文数: 2.3W
被引数: 600
引用论文

引用论文

Mathematical creation
err2017-03-14
err0
PREAI
errHenri Poincaré
err分享
err收藏
err分享
err收藏
Chaperone Priming of Pilus Subunits Facilitates a Topological Transition that Drives Fiber Formation
errCell
IF0
err2002-11-01
err0
errOAAI
errFrederic G. Sauer; Jerome S. Pinkner; Gabriel Waksman; Scott J. Hultgren
err分享
err收藏
err分享
err收藏
学者 查看更多内容