Knowledge-based planning for Gamma Knife

delete2024-04-10
delete0
PRE
AI
B
Binghao Zhang *
A
Aaron Babier
M
Mark Ruschin
T
Timothy C. Y. Chan
DOI:10.1002/mp.17058delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
BackgroundCurrent methods for Gamma Knife (GK) treatment planning utilizes either manual forward planning, where planners manually place shots in a tumor to achieve a desired dose distribution, or inverse planning, whereby the dose delivered to a tumor is optimized for multiple objectives based on established metrics. For other treatment modalities like IMRT and VMAT, there has been a recent push to develop knowledge-based planning (KBP) pipelines to address the limitations presented by forward and inverse planning. However, no complete KBP pipeline has been created for GK.PurposeTo develop a novel (KBP) pipeline, using inverse optimization (IO) with 3D dose predictions for GK.MethodsData were obtained for 349 patients from Sunnybrook Health Sciences Centre. A 3D dose prediction model was trained using 322 patients, based on a previously published deep learning methodology, and dose predictions were generated for the remaining 27 out-of-sample patients. A generalized IO model was developed to learn objective function weights from dose predictions. These weights were then used in an inverse planning model to generate deliverable treatment plans. A dose mimicking (DM) model was also implemented for comparison. The quality of the resulting plans was compared to their clinical counterparts using standard GK quality metrics. The performance of the models was also characterized with respect to the dose predictions.ResultsAcross all quality metrics, plans generated using the IO pipeline performed at least as well as or better than the respective clinical plans. The average conformity and gradient indices of IO plans was 0.737 +/-$\pm$ 0.158 and 3.356 +/-$\pm$ 1.030 respectively, compared to 0.713 +/-$\pm$ 0.124 and 3.452 +/-$\pm$ 1.123 for the clinical plans. IO plans also performed better than DM plans for five of the six quality metrics. Plans generated using IO also have average treatment times comparable to that of clinical plans. With regards to the dose predictions, predictions with higher conformity tend to result in higher quality KBP plans.ConclusionsPlans resulting from an IO KBP pipeline are, on average, of equal or superior quality compared to those obtained through manual planning. The results demonstrate the potential for the use of KBP to generate GK treatment with minimal human intervention.
Keyword:
Gamma Knife
knowledge-based planning
optimization

期刊

Medical Physics 封面图
Medical Physics
IF:
3.2
论文数:
3.7W
被引数:
3.2W

机构

U
university of toronto
学者数:
14.8W
论文数: 12.0W
被引数: 165
引用论文

引用论文

Promoting dye-sorghum for local and global markets
err2023-03-01
err0
PREAI
errA.P.P. Kayodé; M.J.R. Nout; A.R. Linnemann
err分享
err收藏
The importance of evaluating the complete automated knowledge-based planning pipeline
err2020-04-01
err25
errOAAI
errBabier, Aaron; Mahmood, Rafid; McNiven, Andrea L.; Diamant, Adam; Chan, Timothy C. Y.
err分享
err收藏
A linear programming approach to inverse planning in Gamma Knife radiosurgery
err2019-03-08
err34
errOAAI
errSjolund, J.; Riad, S.; Hennix, M.; Nordstrom, H.
err分享
err收藏
err分享
err收藏
Automated treatment planning for a dedicated multi-source intracranial radiosurgery treatment unit using projected gradient and grassfire algorithms
err2012-05-15
err35
PREAI
errGhobadi, Kimia; Ghaffari, Hamid R.; Aleman, Dionne M.; Jaffray, David A.; Ruschin, Mark
err分享
err收藏
学者 查看更多内容