arrow
返回

Line scan diffusion imaging

delete2005-12-12
delete237
PRE
AI
H
Hákon Guðbjartsson *
S
Stephan E. Maier
R
Robert V. Mulkern
I
I Mórocz
S
Samuel Patz
F
Ferenc A. Jólesz
DOI:10.1002/mrm.1910360403delete
delete原文链接
delete分享
delete收藏
摘要

摘要

En 中文
A novel line scan diffusion imaging sequence (LSDI) is introduced. LSDI is inherently insensitive to motion artifacts and high quality diffusion maps of the brain can be obtained rapidly without the use of head restraints or cardiac gating, Results from a stroke study and abdominal diffusion images are presented. The results indicate that it is feasible to use the LSDI technique for clinical evaluation of acute ischemic stroke, In contrast to echo-planar diffusion imaging, LSDI does not require modified gradient hardware and can be implemented on conventional scanners. Thus, LSDI should dramatically increase the general availability of robust clinical diffusion imaging.
Keyword:
diffusion imaging
line scan
LSDI, stroke imaging
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

Double line scan diffusion imaging
err2005-12-12
err14
PREAI
errGudbjartsson, H; Maier, SE; Jolesz, FA
err分享
err收藏
err分享
err收藏
Line-scan diffusion tensor MR imaging at 0.2 T: Feasibility study
err2005-11-03
err9
errOAAI
errHori, M; Aoki, S; Okubo, T; Ishigame, K; Kumagai, H; Araki, T
err分享
err收藏
Comparison of single-shot echo-planar and line scan protocols for diffusion tensor-imaging扩散张量成像的单次回波平面和线扫描协议的比较
err2004-02-01
err25
errOAAI
errKubicki, M; Maier, SE; Westin, CF; Mamata, H; Ersner-Hershfield, H; Estepar, R; Kikinis, R; Jolesz, FA; McCarley, RW; Shenton, ME
err分享
err收藏

期刊

Magnetic Resonance in Medicine 封面图
Magnetic Resonance in Medicine
IF:
3
论文数:
1.2W
被引数:
3.8W

机构

暂无机构信息
引用论文

引用论文

err分享
err收藏
Highly stable Zn anodes realized by 3D zincophilic and hydrophobic interphase buffer layer通过3D zincophilic和疏水性相间缓冲层实现的高度稳定的Zn阳极
err2024-09-01
err0
errOAAI
errYunfei Shen; Pengjie Fu; Jianjie Liu; Kaisheng Sun; Huanzhang Wen; Ping Liu; Heng Lv; Tiantian Gu; Xiaodong Yang; Long Chen
err分享
err收藏
ECHO-PLANAR IMAGING OF INTRAVOXEL INCOHERENT MOTION
errRADIOLOGY
IF15.2
err1990-11-01
err510
PREAI
errTURNER, R; LEBIHAN, D; MAIER, J; VAVREK, R; HEDGES, LK; PEKAR, J
err分享
err收藏
Ineffectiveness of cognitive forcing strategies to reduce biases in diagnostic reasoning: a controlled trial
errCJEM
IF0
err2015-03-04
err0
errOAAI
errJonathan Sherbino; Kulamakan Kulasegaram; Elizabeth Howey; Geoffrey Norman
err分享
err收藏
Length‐Dependent Band‐Gap Shift of TiO32− Molecular Wires Embedded in Zeolite ETS‐10
err2007-07-25
err0
PREAI
errNak Cheon Jeong; Myoung Hee Lee; Kyung Byung Yoon
err分享
err收藏
What causes chronic fatigue syndrome?
errBMJ
IF0
err2004-10-21
err0
errOAAI
errPeter D White
err分享
err收藏
学者 查看更多内容