Linearized Data Center Workload and Cooling Management

delete2025-01-01
delete1
delete
OA
AI
S
Somayye Rostami *
D
Douglas G. Down
G
George Karakostas
DOI:10.1109/TASE.2024.3395471delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
With the current high levels of energy consumption of data centers, reducing power consumption by even a small percentage is beneficial. We propose a framework for thermal-aware workload distribution in a data center to reduce cooling power consumption. The framework includes linearization of the general optimization problem and proposing a heuristic to approximate the solution for the resulting Mixed Integer Linear Programming (MILP) problems. We first define a general nonlinear power optimization problem including several cooling parameters, heat recirculation effects, and constraints on server temperatures. We propose to study a linearized version of the problem, which is easier to analyze. As an energy saving scenario and as a proof of concept for our approach, we also consider the possibility that the red-line temperature for idle servers is higher than that for busy servers. For the resulting MILP problem, we propose a heuristic for intelligent rounding of the fractional solution. Through numerical simulations, we compare our heuristics with several existing algorithms. In addition, we evaluate the performance of the solution of the linearized system on the original system. Finally, the results show that the proposed approach can reduce the cooling power consumption by more than 10 percent compared to the case of continuous utilizations and a single red-line temperature. Note to Practitioners-We present a holistic approach for thermal-aware workload distribution for power consumption reduction in data centers. We suggest that when thermal and power consumption models can be linearized, a model-independent approach can be used for optimization purposes. The standard linear problem that results presents some technical challenges to solve, for which we present intuitive and effective solution heuristics. The heuristics are simple enough that they could be used for real-time calculations. The result is that customized models and problems can be avoided (a linear model could be directly constructed from operational data, if available), allowing for the simplification of operational control problems. Our approach is evaluated for a high-fidelity model of a real data center, where both the linearization and optimization components are validated. Finally, we show how this approach can be used to effectively solve the operational problem of workload distribution in the presence of utilization-dependent server red-line temperatures.
Keyword:
Data center
thermal-aware workload distribution
integer programming
linearization
cooling power consumption
red-line temperatures

期刊

IEEE Transactions on Automation Science and Engineering 封面图
IEEE Transactions on Automation Science and Engineering
IF:
6.4
论文数:
5.0K
被引数:
1.6W

机构

M
McMaster University
学者数:
3.6W
论文数: 3.3W
被引数: 4.4W
引用论文

引用论文

Modeling temperature distribution and power consumption in IT server enclosures with row-based cooling architectures
err2020-03-01
err40
errOAAI
errMoazamigoodarzi, Hosein; Gupta, Rohit; Pal, Souvik; Tsai, Peiying Jennifer; Ghosh, Suvojit; Puri, Ishwar K.
err分享
err收藏
err分享
err收藏
Latency and Energy-Aware Load Balancing in Cloud Data Centers: A Bargaining Game Based Approach
err2023-01-01
err14
PREAI
errKishor, Avadh; Niyogi, Rajdeep; Chronopoulos, Anthony Theodore; Zomaya, Albert Y.
err分享
err收藏
A coupled model of wellbore-formation thermal phenomena and salt creep in offshore wells
err2024-02-01
err0
PREAI
errEduardo B.D.M. Alves; Arthur P. da Veiga; Eduardo A. Fancello; Jader R. Barbosa
err分享
err收藏
A Game-based Thermal-Aware Resource Allocation Strategy for Data Centers一种基于博弈的数据中心热感知资源分配策略
err2021-07-01
err23
PREAI
errAkbar, Saeed; Malik, Saif Ur Rehman; Choo, Kim-Kwang Raymond; Khan, Samee U.; Ahmad, Naveed; Anjum, Adeel
err分享
err收藏
err分享
err收藏
err分享
err收藏
学者 查看更多内容