arrow
返回

Material-level countermeasures for securing microfluidic biochips

delete2023-01-01
delete6
PRE
AI
N
Navajit Singh Baban *
S
Sohini Saha
S
Sofija Jancheska
I
Inderjeet Singh
S
Sachin Khapli
M
Maksat Khobdabayev
J
Jongmin Kim
S
Sukanta Bhattacharjee
Y
Yong‐Ak Song
K
Krishnendu Chakrabarty
R
Ramesh Karri
DOI:10.1039/d3lc00335cdelete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Flow-based microfluidic biochips (FMBs) have been rapidly commercialized and deployed in recent years for biological computing, clinical diagnostics, and point-of-care-tests (POCTs). However, outsourcing FMBs makes them susceptible to material-level attacks by malicious actors for illegitimate monetary gain. The attacks involve deliberate material degradation of an FMB's polydimethylsiloxane (PDMS) components by either doping with reactive solvents or altering the PDMS curing ratio during fabrication. Such attacks are stealthy enough to evade detection and deteriorate the FMB's function. Furthermore, material-level attacks can become prevalent in attacks based on intellectual property (IP) theft, such as counterfeiting, overbuilding, etc., which involve unscrupulous third-party manufacturers. To address this problem, we present a dynamic material-level watermarking scheme for PDMS-based FMBs with microvalves using a perylene-labeled fluorescent dye. The dyed microvalves show a unique excimer intensity peak under 405 nm laser excitation. Moreover, when pneumatically actuated, the peak shows a predetermined downward shift in intensity as a function of mechanical strain. We validated this protection scheme experimentally using fluorescence microscopy, which showed a high correlation (R-2 = 0.971) between the normalized excimer intensity change and the maximum principal strain of the actuated microvalves. To detect curing ratio-based attacks, we adapted machine learning (ML) models, which were trained on the force-displacement data obtained from a mechanical punch test method. Our ML models achieved more than 99% accuracy in detecting curing ratio anomalies. These countermeasures can be used to proactively safeguard FMBs against material-level attacks in the era of global pandemics and diagnostics based on POCTs.
Keyword:
ANOMALY DETECTION
NEURAL-NETWORKS
LOCALIZATION
ADHESIVE
DEFENSES

期刊

L
Lab on a Chip
IF:
5.4
论文数:
9.0K
被引数:
3.3W

机构

D
Duke University
学者数:
6.3W
论文数: 5.7W
被引数: 6.5W
N
New York University
学者数:
4.4W
论文数: 3.9W
被引数: 5.8W
I
indian institute of technology (iit) - guwahati
学者数:
3.3K
论文数: 3.2K
被引数: 2
N
New York University Abu Dhabi
学者数:
2.1K
论文数: 1.5K
被引数: 3.3K
学者 查看更多机构
引用论文

引用论文

A lab-on-a-chip that takes the chip out of the lab
errNATURE
IF48.5
err2022-05-18
err9
PREAI
errMohammed, Mazher Iqbal
err分享
err收藏
Carbon Deposition of Biotar from Pine Sawdust by Chemical Vapor Infiltration on Steelmaking Slag as a Supplementary Fuel in Steelworks
err2012-06-07
err0
PREAI
errAlya N. Rozhan; Rochim B. Cahyono; Naoto Yasuda; Takahiro Nomura; Sou Hosokai; Tomohiro Akiyama
err分享
err收藏
Measuring the effect of the COVID-19 pandemic on solid organ transplantation
err2022-07-01
err0
errOAAI
errAlejandro Suarez-Pierre; Rashikh Choudhury; Adam M. Carroll; Robert W. King; John Iguidbashian; Jake Cotton; Kathryn L. Colborn; Peter T. Kennealey; Joseph C. Cleveland; Elizabeth Pomfret; David A. Fullerton
err分享
err收藏
The Jahn-Teller effect in the SrLaGa3O7:Co2+system
err2001-01-11
err0
PREAI
errMarek Grinberg; Slawomir M Kaczmarek; Marek Berkowski; Taiju Tsuboi
err分享
err收藏
Mechanochromic polyurethane strain sensor
err2014-08-14
err36
PREAI
errCellini, F.; Khapli, S.; Peterson, S. D.; Porfiri, M.
err分享
err收藏
A novel architecture combined with optimal parameters for back propagation neural networks applied to anomaly network intrusion detection
err2018-06-01
err67
PREAI
errChiba, Zouhair; Abghour, Noureddine; Moussaid, Khalid; El Omri, Amina; Rida, Mohamed
err分享
err收藏
Stereo Matching Methods for Imperfectly Rectified Stereo Images
err2019-04-19
err0
errOAAI
errPhuc Hong Nguyen; Chang Wook Ahn
err分享
err收藏
学者 查看更多内容