返回
MEMS-based voltage detector
DOI:10.1016/j.sna.2015.08.011.png)
摘要
En 中文
A novel principle of low-noise voltage measurement based on microelectromechanical systems (MEMS) is introduced and experimentally demonstrated. The method is based on parametric conversion of voltage via electromechanical force to the amplitude of the RF signal of the capacitive measurement circuit that detects the displacement of a moving-plate MEMS capacitor. Both theory and experiments show that the noise of voltage measurement can be considerably decreased by biasing the MEMS device near its pull-in point. Experimental results are in agreement with theoretical predictions and they indicate the potential of the method as a competitor of state-of-the-art low-noise voltmeters in special applications. (C) 2015 Elsevier B.V. All rights reserved.
Keyword:
Capacitive sensors
MEMS
Readout
Pull-in
Noise
Voltage measurement
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
4.9
论文数:
1.5W
被引数:
3.3W
机构