arrow
返回

Micro photoionization detectors

delete2019-05-01
delete48
PRE
AI
G
Gustavo Coelho Rezende
S
Stéphane Le Calvé
J
Jürgen J. Brandner
D
David Newport *
DOI:10.1016/j.snb.2019.01.072delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
There is an increased awareness of the detrimental effect exposure to Volatile Organic Compounds (VOCs) have on human health, that has led a demand for portable, fast, and high performance gas analysis systems. In many cases, this involves the use of photoionization detection technology, which provides a rapid and precise analysis. Miniaturization of photoionization detectors can contribute to develop improved gas analysers through increased portability, reduced resource consumption, and enhanced sensitivity. This paper presents a review of recent developments in photoionization detector miniaturization, where most of the devices are compatible with microfluidic arrangements. The design, dimensions, microfabrication, operation, and performance of the miniaturized photoionization detectors are reported. In addition, a background theory of the classical photoionization detector, including brief design guidelines, is also provided. The reported miniaturized devices present ionization chamber volumes up to 50 times lower than commercially available devices and hold potential for faster analysis and lower detection limit.
Keyword:
Photoionization detector
Miniaturization
Microfabrication
Gas chromatography
VOC detection
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Sensors and Actuators B-Chemical 封面图
Sensors and Actuators B-Chemical
IF:
7.7
论文数:
3.4W
被引数:
12.6W

机构

U
University of Limerick
学者数:
7.4K
论文数: 6.6K
被引数: 7.4K
C
centre national de la recherche scientifique (cnrs)
学者数:
24.5W
论文数: 18.2W
被引数: 279
H
Helmholtz Association
学者数:
13.2W
论文数: 10.7W
被引数: 145
学者 查看更多机构
引用论文

引用论文

In situ calibration of micro-photoionization detectors in a multi-dimensional micro-gas chromatography system
errANALYST
IF3.3
err2016-01-01
err25
PREAI
errLee, Jiwon; Zhou, Menglian; Zhu, Hongbo; Nidetz, Robert; Kurabayashi, Katsuo; Fan, Xudong
err分享
err收藏
Fully Automated Portable Comprehensive 2-Dimensional Gas Chromatography Device
err2016-10-06
err46
PREAI
errLee, Jiwon; Zhou, Menglian; Zhu, Hongbo; Nidetz, Robert; Kurabayashi, Katsuo; Fan, Xudong
err分享
err收藏
Assessment of soil buffer capacity on nutrients and pharmaceuticals in nature-based solution applications
err2018-11-10
err0
PREAI
errAlessio Barbagli; Benjamin Niklas Jensen; Muhammad Raza; Christoph Schüth; Rudy Rossetto
err分享
err收藏
err分享
err收藏
Acute and chronicin vivoeffects of exposure to nicotine and propylene glycol from an E-cigarette on mucociliary clearance in a murine model
err2017-06-26
err0
errOAAI
errBeth L. Laube; Nima Afshar-Mohajer; Kirsten Koehler; Gang Chen; Philip Lazarus; Joseph M. Collaco; Sharon A. McGrath-Morrow
err分享
err收藏
学者 查看更多内容