arrow
返回

Micromachined polymer-based chemical gas sensor array

delete2001-01-01
delete210
PRE
AI
F
F. Zee *
J
Jack W. Judy
DOI:10.1016/S0925-4005(00)00638-9delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
We have developed a miniature polymer-based chemical gas sensor array on silicon using micromachining technology. The sensors are polymer-carbon black composite films, which swell reversibly and cause a resistance change upon exposure to a wide variety of gases. We have fabricated two types of devices which can measure this resistance change using a well design. These wells contain the polymer-carbon black-solvent liquid volume present during deposition and allow the sensor him to be placed reproducibly in a specific and well-constrained area. After deposition, the solvents evaporate and leave behind a polymer-carbon black residue crust between metal leads on each side of the well. Two types of devices, a bulk micromachined sensor and a patterned thick-film sensor, have been fabricated, ranging in size from 500 mum x 600 mum to 100 mum x 100 mum. Since the composite him sensors are not specific to any one gas, an array of these sensors, each with a different sensing him, is used to identify gases and gas mixtures through the pattern response of the array Six polymer-carbon black composite films were deposited into the sensor array and exposed to three chemical gases at five different concentration levels. The sensors were able to uniquely detect these gas vapors and demonstrated a linear response to concentration levels between 2000 and 10,000 ppm. Results also indicate that a reduction in sensor area by an order of magnitude (from 4.32 to 0.30 mm(2)) does not reduce sensor response. This design allows the integration of circuits to process the changes in resistance which will permit the realization of a completely integrated miniature gas sensor. (C) 2001 Published by Elsevier Science B.V.
Keyword:
electronic nose
gas sensor
polymer/carbon black
MEMS
SU-8
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Sensors and Actuators B-Chemical 封面图
Sensors and Actuators B-Chemical
IF:
7.7
论文数:
3.4W
被引数:
12.6W

机构

暂无机构信息
引用论文

引用论文

err
IF0
err
err0
PREAI
err
err分享
err收藏
Frequency and Risk Factors for Under- and Over-Treatment in Stroke Prevention for Patients with Non-Valvular Atrial Fibrillation in General Practice
err2013-07-05
err0
errOAAI
errDerk L. Arts; Stefan Visscher; Wim Opstelten; Joke C. Korevaar; Ameen Abu-Hanna; Henk C. P. M. van Weert
err分享
err收藏
err分享
err收藏
Array-based vapor sensing using chemically sensitive, carbon black-polymer resistors
err1996-09-12
err645
errOAAI
errLonergan, MC; Severin, EJ; Doleman, BJ; Beaber, SA; Grubb, RH; Lewis, NS
err分享
err收藏
没有更多内容