返回
Misalignment Error Suppression Between Host Frame and Magnetic Sensor Array
DOI:10.1109/TIM.2020.3011764.png)
摘要
En 中文
Magnetic sensor array is usually designed for object detection and localization, where sensor coordinate is required to be consistent. Misalignment angles between coordinates should be calculated and calibrated. A new calibration method is proposed in order to calibrate the misalignment error between host frame and sensors. Host platform frame and perpendicular platform are used to obtain misalignment angles of sensor array. Experiment results show that it can estimate all angles of magnetic sensors and suppress misalignment error. Misalignment rms error is a reduction from 1109.7 to 27.6 nT, which means 2.48% indeed, thus improving the remote sensing accuracy of array which is unified to host frame coordinate.
Keyword:
Host frame coordinate
misalignment error
sensor array
suppression
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
5.9
论文数:
2.0W
被引数:
5.8W
机构
引用论文
Sociale reproductie in een tijdperk van mondialisering. Wie kiest er voor het tweetalig onderwijs? /Social Reproduction in the Era of Globalization: Who Opts for Bilingual Education?
Sociologie
IF0
One-step calibration of magnetic gradient tensor system with nonlinear least square method磁梯度张量系统的非线性最小二乘法一步标定