arrow
返回

Model-based denoising in diffusion-weighted imaging using generalized spherical deconvolution

delete2017-02-28
delete13
delete
OA
AI
J
Jonathan I. Sperl *
T
Tim Sprenger
E
Ek T. Tan
M
Marion I. Menzel
C
Christopher J. Hardy
L
Luca Marinelli
DOI:10.1002/mrm.26626delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
PurposeDiffusion MRI often suffers from low signal-to-noise ratio, especially for high b-values. This work proposes a model-based denoising technique to address this limitation. MethodsA generalization of the multi-shell spherical deconvolution model using a Richardson-Lucy algorithm is applied to noisy data. The reconstructed coefficients are then used in the forward model to compute denoised diffusion-weighted images (DWIs). The proposed method operates in the diffusion space and thus is complementary to image-based denoising methods. ResultsWe demonstrate improved image quality on the DWIs themselves, maps of neurite orientation dispersion and density imaging, and diffusional kurtosis imaging (DKI), as well as reduced spurious peaks in deterministic tractography. For DKI in particular, we observe up to 50% error reduction and demonstrate high image quality using just 30 DWIs. This corresponds to greater than fourfold reduction in scan time if compared to the widely used 140-DWI acquisitions. We also confirm consistent performance in pathological data sets, namely in white matter lesions of a multiple sclerosis patient. ConclusionThe proposed denoising technique termed generalized spherical deconvolution has the potential of significantly improving image quality in diffusion MRI. Magn Reson Med 78:2428-2438, 2017. (c) 2017 International Society for Magnetic Resonance in Medicine.
Keyword:
diffusion weighted imaging
denoising
spherical deconvolution
compressed sensing
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Magnetic Resonance in Medicine 封面图
Magnetic Resonance in Medicine
IF:
3
论文数:
1.2W
被引数:
3.1W

机构

G
General Electric
学者数:
4.4K
论文数: 3.4K
被引数: 2
引用论文

引用论文

Q-ball reconstruction of multimodal fiber orientations using the spherical harmonic basis
err2006-06-05
err328
PREAI
errHess, Christopher P.; Mukherjee, Pratik; Han, Eric T.; Xu, Duan; Vigneron, Daniel B.
err分享
err收藏
An in vitro assessment of type, position and incidence of isthmus in human permanent molars体外评估人类恒磨牙中峡的类型、位置及发生率
err2014-07-01
err0
errOAAI
errFernando José Camello de LIMA; Francisco MONTAGNER; Rogério Castilho JACINTO; Glaucia Maria Bovi AMBROSANO; Brenda Paula Figueiredo de Almeida GOMES
err分享
err收藏
Noise correction on Rician distributed data for fibre orientation estimators
err2008-09-01
err24
PREAI
errClarke, Rafael Alonso; Scifo, Paola; Rizzo, Giovanna; Dell'Acqua, Flavio; Scotti, Giuseppe; Fazio, Ferruccio
err分享
err收藏
Multi-shell diffusion signal recovery from sparse measurements
err2014-10-01
err40
errOAAI
errRathi, Y.; Michailovich, O.; Laun, F.; Setsompop, K.; Grant, P. E.; Westin, C. -F.
err分享
err收藏
Accelerated Diffusion Spectrum Imaging in the Human Brain Using Compressed Sensing
err2011-08-16
err112
errOAAI
errMenzel, Marion I.; Tan, Ek T.; Khare, Kedar; Sperl, Jonathan I.; King, Kevin F.; Tao, Xiaodong; Hardy, Christopher J.; Marinelli, Luca
err分享
err收藏
Methodological comparison of calibration procedures for durum wheat parameters in the STICS model
err2011-10-01
err0
PREAI
errSolenne Guillaume; Jacques-Eric Bergez; Daniel Wallach; Eric Justes
err分享
err收藏
err分享
err收藏
学者 查看更多内容