arrow
返回

Modeling studies on irregular motor unit potentials

delete2004-03-01
delete26
PRE
AI
E
Ewa Zalewska
I
I Hausmanowa-Pétrusewicz
S
Ståhlberg, E
DOI:10.1016/j.clinph.2003.10.031delete
delete原文链接
delete分享
delete收藏
摘要

摘要

En 中文
Objective: The aim of these modeling studies on the generation of motor unit potentials (MUPs) was to establish the influence of MU parameters and recording conditions on the shape irregularity of MUPs. The focus was on the dependence of the irregularity of MUPs on fiber density, fiber diameters and the recording distance from the end-plate zone. Methods: The study was performed using the 'EMG Simulator' software for modeling of MUP and our own software for calculations. Results: The results indicate that the irregularity of a MUP increases with increased recording distance from the end-plate zone and decreases with increased fiber diameter and/or with increased fiber density. The quantitative relationship between these factors has been derived. Conclusions: The relationships determine the structural conditions in which irregular potential may be generated and therefore may be helpful in the interpretation of atypical MUPs. (C) 2003 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Keyword:
simulation
motor unit potential
concentric needle EMG
irregularity
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Clinical Neurophysiology 封面图
Clinical Neurophysiology
IF:
3.6
论文数:
9.3K
被引数:
2.1W

机构

暂无机构信息
引用论文

引用论文

Adipates
err2013-01-01
err0
PREAI
errAnna Wypych
err分享
err收藏
err分享
err收藏
Accuracy of Clinical Evaluation in Pediatric Obstructive Sleep Apnea
err2016-11-21
err0
PREAI
errRobert C. Wang; Tina P. Elkins; Daniel Keech; Albert Wauquier; Douglas Hubbard
err分享
err收藏
学者 查看更多内容