Modeling studies on irregular motor unit potentials
DOI:10.1016/j.clinph.2003.10.031.png)
摘要
En 中文
Objective: The aim of these modeling studies on the generation of motor unit potentials (MUPs) was to establish the influence of MU parameters and recording conditions on the shape irregularity of MUPs. The focus was on the dependence of the irregularity of MUPs on fiber density, fiber diameters and the recording distance from the end-plate zone. Methods: The study was performed using the 'EMG Simulator' software for modeling of MUP and our own software for calculations. Results: The results indicate that the irregularity of a MUP increases with increased recording distance from the end-plate zone and decreases with increased fiber diameter and/or with increased fiber density. The quantitative relationship between these factors has been derived. Conclusions: The relationships determine the structural conditions in which irregular potential may be generated and therefore may be helpful in the interpretation of atypical MUPs. (C) 2003 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Keyword:
simulation
motor unit potential
concentric needle EMG
irregularity
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
3.6
论文数:
9.3K
被引数:
2.1W