MOQUI: an open-source GPU-based Monte Carlo code for proton dose calculation with efficient data structure
DOI:10.1088/1361-6560/ac8716.png)
摘要
En 中文
Objective. Monte Carlo (MC) codes are increasingly used for accurate radiotherapy dose calculation. In proton therapy, the accuracy of the dose calculation algorithm is expected to have a more significant impact than in photon therapy due to the depth-dose characteristics of proton beams. However, MC simulations come at a considerable computational cost to achieve statistically sufficient accuracy. There have been efforts to improve computational efficiency while maintaining sufficient accuracy. Among those, parallelizing particle transportation using graphic processing units (GPU) achieved significant improvements. Contrary to the central processing unit, a GPU has limited memory capacity and is not expandable. It is therefore challenging to score quantities with large dimensions requiring extensive memory. The objective of this study is to develop an open-source GPU-based MC package capable of scoring those quantities. Approach. We employed a hash-table, one of the key-value pair data structures, to efficiently utilize the limited memory of the GPU and score the quantities requiring a large amount of memory. With the hash table, only voxels interacting with particles will occupy memory, and we can search the data efficiently to determine their address. The hash-table was integrated with a novel GPU-based MC code, moqui. Main results. The developed code was validated against an MC code widely used in proton therapy, TOPAS, with homogeneous and heterogeneous phantoms. We also compared the dose calculation results of clinical treatment plans. The developed code agreed with TOPAS within 2%, except for the fall-off and regions, and the gamma pass rates of the results were >99% for all cases with a 2 mm/2% criteria. Significance. We can score dose-influence matrix and dose-rate on a GPU for a 3-field H&N case with 10 GB of memory using moqui, which would require more than 100 GB of memory with the conventionally used array data structure.
Keyword:
Monte Carlo
graphic processing unit
proton therapy
期刊
IF:
3.4
论文数:
1.4W
被引数:
3.1W
机构
引用论文
Efficiency improvement in proton dose calculations with an equivalent restricted stopping power formalism使用等效的限制停止功率形式主义提高质子剂量计算的效率
A GPU-accelerated and Monte Carlo-based intensity modulated proton therapy optimization system
MEDICAL PHYSICS
IF3.2
Chiral analysis of ammuxetine enantiomers in dog plasma using online SPE/liquid chromatography with tandem mass spectrometric detection after precolumn chiral derivatization
Chirality
IF0
Simultaneous optimization of dose distributions and fractionation schemes in particle radiotherapy
MEDICAL PHYSICS
IF3.2