Motion compensation for aortic valves using partial angle CT reconstructions

delete2022-02-11
delete1
delete
OA
AI
S
Sergej Lebedev
É
Éric Fournié
J
Joscha Maier
K
Karl Stierstorfer
M
Marc Kachelrieß *
DOI:10.1002/mp.15379delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Purpose A motion compensation method that is aimed at correcting motion artifacts of cardiac valves is proposed. The primary focus is the aortic valve. Methods The method is based around partial angle reconstructions and a cost function including the image entropy. A motion model is applied to approximate the cardiac motion in the temporal and spatial domain. Based on characteristic values for velocities and strain during cardiac motion, penalties for the velocity and spatial derivatives are introduced to maintain anatomically realistic motion vector fields and avoid distortions. The model addresses global elastic deformation, but not the finer and more complicated motion of the valve leaflets. Results The method is verified based on clinical data. Image quality was improved for most artifact-impaired reconstructions. An image quality study with Likert scoring of the motion artifact severity on a scale from 1 (highest image quality) to 5 (lowest image quality/extreme artifact presence) was performed. The biggest improvements after applying motion compensation were achieved for strongly artifact-impaired initial images scoring 4 and 5, resulting in an average change of the scores by -0.59 +/- 0.06$-0.59\pm 0.06$ and -1.33 +/- 0.03$-1.33\pm 0.03$, respectively. In the case of artifact-free images, a chance to introduce blurring was observed and their average score was raised by 0.42 +/- 0.03. Conclusion Motion artifacts were consistently removed and image quality improved.
Keyword:
cardiac CT
cardiac valve
motion compensation

期刊

Medical Physics 封面图
Medical Physics
IF:
3.2
论文数:
3.7W
被引数:
3.2W

机构

G
German Cancer Research Center (DKFZ)
学者数:
1.5W
论文数: 1.1W
被引数: 17
H
Helmholtz Association
学者数:
13.2W
论文数: 10.7W
被引数: 145
引用论文

引用论文

Nonrigid registration-based coronary artery motion correction for cardiac computed tomography
err2012-06-22
err50
PREAI
errBhagalia, Roshni; Pack, Jed D.; Miller, James V.; Iatrou, Maria
err分享
err收藏
Adaptive temporal resolution optimization in helical cardiac cone beam CT reconstruction
err2003-11-18
err111
PREAI
errManzke, R; Grass, M; Nielsen, T; Shechter, G; Hawkes, D
err分享
err收藏
Salt Tolerance in the Triticeae:Leymus sabulosus
err1984-01-01
err0
PREAI
errJ. GORHAM; E. MCDONNELL; R. G. WYN JONES
err分享
err收藏
err分享
err收藏
学者 查看更多内容