arrow
返回

Motion Estimation From Surface Electromyogram Using Adaboost Regression and Average Feature Values

delete2019-01-01
delete41
delete
OA
AI
F
Feiyun Xiao *
Y
Yong Wang
L
Liangguo He
W
Wang Hu
W
Weihan Li
Z
Zhengshi Liu
DOI:10.1109/ACCESS.2019.2892780delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
The method to estimate joint motion quickly and accurately from surface electromyogram (sEMG) has been explored by many researchers. However, the effect of different grabbing loads is ignored by most of them, which limits its clinical and daily applicability. In order to eliminate this effect in the course of motion estimation, an Adaboost-AF method based on Adaboost regression was proposed to identify the load information and estimate motion intention. This method is composed of three parts: the sEMG preprocessing part, the load identification part, and the motion intention estimation part. The average value of sEMG feature signal, which is obtained during sEMG preprocessing part, was used to identify the load information. Five features, root mean square (rms), waveform length, difference absolute standard deviation value, the integral signal of sEMG (IEMG), and low-pass filtered signal of sEMG (LPFEMG) similar to sEMG envelope were explored whether the average value of features signal can be used to identify the load under different speeds. After the load was identified, the Adaboost regression framework with the decision tree as the weak learner was applied to be the motion intention estimation part. Experimental results showed that the average rms difference between an actual angle and estimated angle by using the Adaboost-AF method was 0.1193 +/- 0.0148, and the average execution time for a section of data with 17.58 s was 0.3932 +/- 0.0610 s. (Scikit-learn packet was adopted, and the version number was V0.21. The running software was Spyder, Python3.6.) This paper shows that the method based on the average value of sEMG feature signals can eliminate the influence of different loads without adding new sensors; IEMG and LPFEMG from the biceps brachii muscle show the optimal loads identification performance; the proposed Adaboost-AF method takes the influence of different loads into account and ensures the rapid and accurate estimation performance of motion intention.
Keyword:
sEMG
different load
joint angle estimation
adaboost
feature signal
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

IEEE Access 封面图
IEEE Access
IF:
3.6
论文数:
9.8W
被引数:
29.4W

机构

H
hefei university of technology
学者数:
2.5W
论文数: 1.7W
被引数: 35
引用论文

引用论文

An Upper-Limb Power-Assist Exoskeleton Using Proportional Myoelectric Control
errSENSORS
IF3.5
err2014-04-10
err152
errOAAI
errTang, Zhichuan; Zhang, Kejun; Sun, Shouqian; Gao, Zenggui; Zhang, Lekai; Yang, Zhongliang
err分享
err收藏
err分享
err收藏
Plasma Exosomal CXCL7 is a Potential Biomarker for Lung Adenocarcinoma
err2022-01-01
err0
PREAI
errWenting Fang; Jianbin You; Qifeng Xu; Yingfeng Jiang; Haizhou Hu; Falin Chen; Liangyuan Chen
err分享
err收藏
The Integrated Tracking, Referral, and Electronic Decision Support, and Care Coordination (I-TREC) program: scalable strategies for the management of hypertension and diabetes within the government healthcare system of India
err2020-11-09
err0
errOAAI
errShivani A. Patel; Hanspria Sharma; Sailesh Mohan; Mary Beth Weber; Devraj Jindal; Prashant Jarhyan; Priti Gupta; Rakshit Sharma; Mumtaj Ali; Mohammed K. Ali; K. M. Venkat Narayan; Dorairaj Prabhakaran; Yashdeep Gupta; Ambuj Roy; Nikhil Tandon
err分享
err收藏
学者 查看更多内容