arrow
返回

Motion-induced error reduction for binary defocusing profilometry via additional temporal sampling

delete2019-08-06
delete24
delete
OA
AI
Y
Yajun Wang
V
Vignesh Suresh
B
Beiwen Li *
DOI:10.1364/OE.27.023948delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
The recently proposed binary defocusing technique has brought speed breakthroughs for three-dimensional (3D) shape measurement with a digital fringe projection system. Despite this, motion-induced phase error is still inevitable due to the multi-shot nature of the phase-shifting algorithm. To alleviate this problem, this paper proposes a motion-induced error reduction method by taking advantage of additional temporal sampling. Particularly, each illuminated fringe pattern will be captured twice in one projection cycle, resulting in two sets of phase shifted fringe images being obtained. Due to the mechanism of binary defocusing projection, the motion-induced phase error could be effectively separated from the fixed phase shift value by evaluating the difference between the two phase maps. Based on this, an iterative compensation strategy is further applied to compensate the phase error until high-quality phase maps are generated. Meanwhile, different synchronization schemes are also proposed and tested to evaluate the error compensation effects. Both simulation and experiments demonstrated that the proposed methods can substantially reduce motion-introduced measurement errors. Since defocused 1-bit binary patterns are utilized to bypass rigid camera-projector synchronization, this method has potential for high-speed applications. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
Keyword:
3-D SHAPE MEASUREMENT
PHASE
ACCURACY

期刊

Optics Express 封面图
Optics Express
IF:
3.3
论文数:
6.1W
被引数:
14.3W

机构

I
Iowa State University
学者数:
2.1W
论文数: 1.8W
被引数: 2.5W
W
wuhan university
学者数:
8.1W
论文数: 5.8W
被引数: 70
引用论文

引用论文

err2002-01-01
err0
PREAI
errP. Cortés; W. J. Cantwell
err分享
err收藏
Trans-activation of the mouse cytomegalovirus immediate early gene enhancer by ras oncogenes
err1994-07-01
err0
errOAAI
errD. Lembo; A. Angeretti; P. Foresta; G. Gribaudo; M. Gariglio; S. Landolfo
err分享
err收藏
Robust dynamic 3-D measurements with motion-compensated phase-shifting profilometry
err2018-04-01
err192
PREAI
errFeng, Shijie; Zuo, Chao; Tao, Tianyang; Hu, Yan; Zhang, Minliang; Chen, Qian; Gu, Guohua
err分享
err收藏
Flexible 3-D shape measurement using projector defocusing
err2009-10-06
err415
PREAI
errLei, Shuangyan; Zhang, Song
err分享
err收藏
Fringe projection techniques: Whither we are?
err2010-02-01
err1.2K
errOAAI
errGorthi, Sai Siva; Rastogi, Pramod
err分享
err收藏
Motion-induced error compensation for phase shifting profilometry
err2018-05-02
err76
errOAAI
errLiu, Ziping; Zibley, Peter C.; Zhang, Song
err分享
err收藏
err分享
err收藏
Some recent advances on superfast 3D shape measurement with digital binary defocusing techniques
err2014-03-01
err152
PREAI
errLi, Beiwen; Wang, Yajun; Dai, Junfei; Lohry, William; Zhang, Song
err分享
err收藏
Accurate Dynamic 3D Sensing With Fourier-Assisted Phase Shifting
err2015-04-01
err79
PREAI
errCong, Pengyu; Xiong, Zhiwei; Zhang, Yueyi; Zhao, Shenghui; Wu, Feng
err分享
err收藏
学者 查看更多内容