MRSCloud: A cloud-based MRS tool for basis set simulation

delete2022-07-01
delete21
PRE
AI
S
Steve C. N. Hui
M
Muhammad G. Saleh
H
Helge J. Zöllner
G
Georg Oeltzschner
H
Hongli Fan
Y
Yue Li
Y
Yulu Song
H
Hangyi Jiang
J
Jamie Near
H
Hanzhang Lu
S
Susumu Mori
R
Richard A.E. Edden *
DOI:10.1002/mrm.29370delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Purpose The purpose of this study is to present a cloud-based spectral simulation tool MRSCloud, which allows MRS users to simulate a vendor-specific and sequence-specific basis set online in a convenient and time-efficient manner. This tool can simulate basis sets for GE, Philips, and Siemens MR scanners, including conventional acquisitions and spectral editing schemes with PRESS and semi-LASER localization at 3 T. Methods The MRSCloud tool was built on the spectral simulation functionality in the FID-A software package. We added three extensions to accelerate computation (ie, one-dimensional projection method, coherence pathways filters, and precalculation of propagators). The RF waveforms were generated based on vendors' generic pulse shapes and timings. Simulations were compared within MRSCloud using different numbers of spatial resolution (21 x 21, 41 x 41, and 101 x 101). Simulated metabolite basis functions from MRSCloud were compared with those generated by the generic FID-A and MARSS, and a phantom-acquired basis set from LCModel. Intraclass correlation coefficients were calculated to measure the agreement between individual metabolite basis functions. Statistical analysis was performed using R in RStudio. Results Simulation time for a full PRESS basis set is approximately 11 min on the server. The interclass correlation coefficients ICCs were at least 0.98 between MRSCloud and FID-A and were at least 0.96 between MRSCloud and MARSS. The interclass correlation coefficients between simulated MRSCloud basis spectra and acquired LCModel basis spectra were lowest for glutamine at 0.68 and highest for N-acetylaspartate at 0.96. Conclusions Substantial reductions in runtime have been achieved. High ICC values indicated that the accelerating features are running correctly and produce comparable and accurate basis sets.
Keyword:
basis set
coherence pathway filtering
density matrix
magnetic resonance spectroscopy
one dimensional projection
simulation

期刊

Magnetic Resonance in Medicine 封面图
Magnetic Resonance in Medicine
IF:
3
论文数:
1.2W
被引数:
3.1W

机构

J
Johns Hopkins University
学者数:
10.2W
论文数: 8.8W
被引数: 13.0W
University System of Maryland 封面图
University System of Maryland
学者数:
6.5W
论文数: 5.6W
被引数: 113
U
university of toronto
学者数:
14.8W
论文数: 12.0W
被引数: 165
学者 查看更多机构
引用论文

引用论文

Fabrication of 3D mesoporous networks of assembled CoO nanoparticles for efficient photocatalytic reduction of aqueous Cr(VI)
err2018-02-01
err0
PREAI
errGeorgia Velegraki; Jianwei Miao; Charalampos Drivas; Bin Liu; Stella Kennou; Gerasimos S. Armatas
err分享
err收藏
err分享
err收藏
Clinical Proton MR Spectroscopy in Central Nervous System Disorders中枢神经系统疾病的临床质子磁共振波谱
errRADIOLOGY
IF15.2
err2014-03-01
err473
errOAAI
errOZ, Gulin; Alger, Jeffry R.; Barker, Peter B.; Bartha, Robert; Bizzi, Alberto; Boesch, Chris; Bolan, Patrick J.; Brindle, Kevin M.; Cudalbu, Cristina; Dincer, Alp; Dydak, Ulrike; Emir, Uzay E.; Frahm, Jens; Gonzalez, Ramon Gilberto; Gruber, Stephan; Gruetter, Rolf; Gupta, Rakesh K.; Heerschap, Arend; Henning, Anke; Hetherington, Hoby P.; Howe, Franklyn A.; Hueppi, Petra S.; Hurd, Ralph E.; Kantarci, Kejal; Klomp, Dennis W. J.; Kreis, Roland; Kruiskamp, Marijn J.; Leach, Martin O.; Lin, Alexander P.; Luijten, Peter R.; Marjanska, Malgorzata; Maudsley, Andrew A.; Meyerhoff, Dieter J.; Mountford, Carolyn E.; Nelson, Sarah J.; Pamir, M. Necmettin; Pan, Jullie W.; Peet, Andrew C.; Poptani, Harish; Posse, Stefan; Pouwels, Petra J. W.; Ratai, Eva-Maria; Ross, Brian D.; Scheenen, Tom W. J.; Schuster, Christian; Smith, Ian C. P.; Soher, Brian J.; Tkac, Ivan; Vigneron, Daniel B.; Kauppinen, Risto A.
err分享
err收藏
err
IF0
err
err0
PREAI
err
err分享
err收藏
学者 查看更多内容