arrow
返回

MUlti-Dimensional Spline-Based Estimator (MUSE) for Motion Estimation: Algorithm Development and Initial Results

delete2008-09-20
delete21
delete
OA
AI
F
Francesco Viola *
R
Ryan L. Coe
K
Kevin Owen
D
Drake A. Guenther
W
William F. Walker
DOI:10.1007/s10439-008-9564-2delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Image registration and motion estimation play central roles in many fields, including RADAR, SONAR, light microscopy, and medical imaging. Because of its central significance, estimator accuracy, precision, and computational cost are of critical importance. We have previously presented a highly accurate, spline-based time delay estimator that directly determines sub-sample time delay estimates from sampled data. The algorithm uses cubic splines to produce a continuous representation of a reference signal and then computes an analytical matching function between this reference and a delayed signal. The location of the minima of this function yields estimates of the time delay. In this paper we describe the MUlti-dimensional Spline-based Estimator (MUSE) that allows accurate and precise estimation of multi-dimensional displacements/strain components from multi-dimensional data sets. We describe the mathematical formulation for two- and three-dimensional motion/strain estimation and present simulation results to assess the intrinsic bias and standard deviation of this algorithm and compare it to currently available multi-dimensional estimators. In 1000 noise-free simulations of ultrasound data we found that 2D MUSE exhibits maximum bias of 2.6 x 10-4 samples in range and 2.2 x 10-3 samples in azimuth (corresponding to 4.8 and 297 nm, respectively). The maximum simulated standard deviation of estimates in both dimensions was comparable at roughly 2.8 x 10-3 samples (corresponding to 54 nm axially and 378 nm laterally). These results are between two and three orders of magnitude better than currently used 2D tracking methods. Simulation of performance in 3D yielded similar results to those observed in 2D. We also present experimental results obtained using 2D MUSE on data acquired by an Ultrasonix Sonix RP imaging system with an L14-5/38 linear array transducer operating at 6.6 MHz. While our validation of the algorithm was performed using ultrasound data, MUSE is broadly applicable across imaging applications.
Keyword:
Motion estimation
Image registration
Strain estimation
Elasticity imaging
Splines

期刊

Annals of Biomedical Engineering 封面图
Annals of Biomedical Engineering
IF:
5.4
论文数:
6.3K
被引数:
1.4W

机构

U
University of Virginia
学者数:
3.0W
论文数: 2.7W
被引数: 4.1W
引用论文

引用论文

Synthesis of optically active (+)-D-3,4,5-tri O-phenylcarbamoyl Myo-inositol from phytic acid
err1995-10-01
err0
PREAI
errCorinne Blum; Susanne Karlsson; Gilbert Schlewer; Bernard Spiess; Nicola Rehnberg
err分享
err收藏
err分享
err收藏
学者 查看更多内容