Multi-focused microlens array optimization and light field imaging study based on Monte Carlo method
DOI:10.1364/OE.25.008274.png)
摘要
En 中文
Plenoptic cameras are used for capturing flames in studies of high-temperature phenomena. However, simulations of plenoptic camera models can be used prior to the experiment improve experimental efficiency and reduce cost. In this work, microlens arrays, which are based on the established light field camera model, are optimized into a hexagonal structure with three types of microlenses. With this improved plenoptic camera model, light field imaging of static objects and flame are simulated using the calibrated parameters of the Raytrix camera (R29). The optimized models improve the image resolution, imaging screen utilization, and shooting range of depth of field. (C) 2017 Optical Society of America
Keyword:
RADIATIVE-TRANSFER
SIMULATION
SYSTEMS
CAMERA
MEDIA
POWER
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
3.3
论文数:
6.1W
被引数:
14.3W
机构
引用论文
Three-dimensional temperature field measurement of flame using a single light field camera
OPTICS EXPRESS
IF3.3
Daily vs. Periodic Nitrogen Addition Affects Growth and Tissue Nitrogen in Perennial Ryegrass Turf
Crop Science
IF0