返回
Multicenter PET image harmonization using generative adversarial networks
DOI:10.1007/s00259-024-06708-8.png)
摘要
En 中文
Purpose To improve reproducibility and predictive performance of PET radiomic features in multicentric studies by cycle-consistent generative adversarial network (GAN) harmonization approaches.Methods GAN-harmonization was developed to harmonize whole-body PET scans to perform image style and texture translation between different centers and scanners. GAN-harmonization was evaluated by application to two retrospectively collected open datasets and different tasks. First, GAN-harmonization was performed on a dual-center lung cancer cohort (127 female, 138 male) where the reproducibility of radiomic features in healthy liver tissue was evaluated. Second, GAN-harmonization was applied to a head and neck cancer cohort (43 female, 154 male) acquired from three centers. Here, the clinical impact of GAN-harmonization was analyzed by predicting the development of distant metastases using a logistic regression model incorporating first-order statistics and texture features from baseline 18F-FDG PET before and after harmonization.Results Image quality remained high (structural similarity: left kidney >= \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\ge$$\end{document} 0.800, right kidney >= \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\ge$$\end{document} 0.806, liver >= \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\ge$$\end{document} 0.780, lung >= \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\ge$$\end{document} 0.838, spleen >= \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\ge$$\end{document} 0.793, whole-body >= \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\ge$$\end{document} 0.832) after image harmonization across all utilized datasets. Using GAN-harmonization, inter-site reproducibility of radiomic features in healthy liver tissue increased at least by >= \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\ge$$\end{document} 5 +/- 14% (first-order), >= \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\ge$$\end{document} 16 +/- 7% (GLCM), >= \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\ge$$\end{document} 19 +/- 5% (GLRLM), >= \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\ge$$\end{document} 16 +/- 8% (GLSZM), >= \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\ge$$\end{document} 17 +/- 6% (GLDM), and >= \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\ge$$\end{document} 23 +/- 14% (NGTDM). In the head and neck cancer cohort, the outcome prediction improved from AUC 0.68 (95% CI 0.66-0.71) to AUC 0.73 (0.71-0.75) by application of GAN-harmonization.Conclusions GANs are capable of performing image harmonization and increase reproducibility and predictive performance of radiomic features derived from different centers and scanners.
Keyword:
Harmonization
Quantitative PET
Multicenter
Generative adversarial networks
Deep learning
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
E
IF:
7.6
论文数:
8.9K
被引数:
2.4W
机构
引用论文
Trp-dependent auxin biosynthesis in Arabidopsis: involvement of cytochrome P450s CYP79B2 and CYP79B3
Evaluation of conventional and deep learning based image harmonization methods in radiomics studies影像组学研究中基于常规和深度学习的图像协调方法的评估
External validation: a simulation study to compare cross-validation versus holdout or external testing to assess the performance of clinical prediction models using PET data from DLBCL patients外部验证: 比较交叉验证与支持或外部测试的模拟研究,以评估使用DLBCL患者的PET数据评估临床预测模型的性能

