arrow
返回

Multilevel computed hemodynamic parameter maps from dynamic perfusion MRI

delete1999-06-01
delete3
PRE
AI
A
Aleksandar Zavaljevski
S
Scott K. Holland
A
Atam P. Dhawan
R
R. Scott Dunn
W
William S. Ball
DOI:10.1109/19.772203delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
A rapid time-series of T2*-weighted magnetic resonance (MR) images acquired during the first pass of a bolus injection of a paramagnetic MR contrast agent provides a basis for estimating cerebral perfusion. The concentration versus time of the contrast agent is calculated in a single image plane on a pixel-wise basis. A number of hemodynamic parameters can be extracted from the integral of the concentration-time curve, hence a method for obtaining an efficient and accurate estimate of the area under the curve is essential for the assessment of perfusion images. A new, automatic, multilevel processing method for calculating area under the concentration-time curve is proposed. In the first level of processing, the signal-to-noise ratio (SNR) is estimated for every pixel, and, if satisfactory, the limit points of integration are determined. An averaging filter is applied on the concentration-time curve, and the slope of the output of the filter is calculated. The thresholds for initial and final integration points are determined next and are used to obtain limit points of integration. At this level, some pixels may be left without computed limits. These are determined at the next level of processing, using the median filter applied on the pixel neighborhood limit points. After determining limit points, the conventional method for integration is used to obtain the area under the curve, Tests of the proposed method are described for both simulated and real data. The simulated data are based on the gamma-variate function, with white noise added. The parameters used are obtained from fitting the gamma-variate function for regions within white matter, gray matter and cerebrospinal fluid in real perfusion images. The results obtained by the proposed estimator compare very favorably with the theoretical values for the particular cases studied. The performance of the proposed method for measuring cerebral hemodynamic parameters is also discussed when applied to perfusion studies in patients performed on a GE Sigma 1.5 T, Advantage, whole body scanner. The results compare well with a previously used procedure based on slice-averaged time of arrival of the contrast bolus and manually determined limiting points. The new method automatizes the integration limit selection procedure efficiently, and is based on local, rather than global calculations. The procedure is simple and fast, and can perform numerical integration of 128*256 pMRI images in less than a second on a Sun SPARC 2 workstation.
Keyword:
dynamic perfusion
estimator
hemodynamic maps
magnetic resonance imaging (MRI)
numerical integration
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

IEEE Transactions on Instrumentation and Measurement 封面图
IEEE Transactions on Instrumentation and Measurement
IF:
5.9
论文数:
2.0W
被引数:
5.8W

机构

暂无机构信息
引用论文

引用论文

The competing role of natural gas and oil as fossil fuel and the non-linear dynamics of resource curse in Russia
err2021-08-01
err0
PREAI
errJinxuan Yang; Syed Kumail Abbas Rizvi; Zhixiong Tan; Muhammad Umar; Mansoor Ahmed Koondhar
err分享
err收藏
FUNCTIONAL IMAGING OF THE BRAIN USING COMPUTED-TOMOGRAPHY
errRADIOLOGY
IF15.2
err1981-03-01
err70
PREAI
errBERNINGER, WH; AXEL, L; NORMAN, D; NAPEL, S; REDINGTON, RW
err分享
err收藏
Finde den Unterschied: synthetische und natürliche Nanopartikel in der Umwelt – Freisetzung, Verhalten und Verbleib
err2014-10-27
err0
errOAAI
errStephan Wagner; Andreas Gondikas; Elisabeth Neubauer; Thilo Hofmann; Frank von der Kammer
err分享
err收藏
Watermarking techniques for intellectual property protection
err2024-03-02
err0
errOAAI
errA.B. Kahng; J. Lach; W.H. Mangione-Smith; S. Mantik; I.L. Markov; M. Potkonjak; P. Tucker; H. Wang; G. Wolfe
err分享
err收藏
学者 查看更多内容