Conventional radiography produces a single image of an object by measuring the attenuation of an x-ray beam passing through it. When imaging weakly absorbing tissues, x-ray attenuation may be a suboptimal signature of disease-related information. In this paper we describe a new phase-sensitive imaging method, called multiple-image radiography (MIR), which is an improvement on a prior technique called diffraction-enhanced imaging (DEI). This paper elaborates on our initial presentation of the idea in Wernick et al (2002 Proc. Int. Symp. Biomed. Imaging pp 129-32). MIR simultaneously produces several images from a set of measurements made with a single x-ray beam. Specifically, MIR yields three images depicting separately the effects of refraction, ultrasmall-angle scatter and attenuation by the object. All three images have good contrast, in part because they are virtually immune from degradation due to scatter at higher angles. MIR also yields a very comprehensive object description, consisting of the angular intensity spectrum of a transmitted x-ray beam at every image pixel, within a narrow angular range. Our experiments are based on data acquired using a synchrotron light source; however, in preparation for more practical implementations using conventional x-ray sources, we develop and evaluate algorithms designed for Poisson noise, which is characteristic of photon-limited imaging. The results suggest that MIR is capable of operating at low photon count levels, therefore the method shows promise for use with conventional x-ray sources. The results also show that, in addition to producing new types of object descriptions, MIR produces substantially more accurate images than its predecessor, DEL MIR results are shown in the form of planar images of a phantom and a biological specimen. A preliminary demonstration of the use of MIR for computed tomography is also presented.
Keyword:
PHASE-CONTRAST
DIFFRACTION
REFRACTION
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Physics in Medicine and Biology 封面图
Physics in Medicine and Biology
IF:
3.4
论文数:
1.4W
被引数:
3.1W

机构

暂无机构信息
引用论文

引用论文

Diffraction enhanced imaging contrast mechanisms in breast cancer specimens
err2002-09-12
err61
errOAAI
errHasnah, MO; Zhong, Z; Oltulu, O; Pisano, E; Johnston, RE; Sayers, D; Thomlinson, W; Chapman, D
err分享
err收藏
Stakeholder perspectives on research and development priorities for mobility assistive-technology: a literature review
err2019-09-19
err0
PREAI
errSaleh Alqahtani; James Joseph; Brad Dicianno; Natasha Ann Layton; Maria Luisa Toro; Eliana Ferretti; Yetsa A. Tuakli-Wosornu; Harvinder Chhabra; Heather Neyedli; Celia Regina Lopes; Mazen M. Alqahtani; Peter Van de Vliet; Shin-Ichiro Kumagaya; Jong-Bae Kim; Vic McKinney; Yu-Sheng Yang; Mary Goldberg; Rory Cooper
err分享
err收藏
Diffraction-enhanced X-ray imaging of articular cartilage
err2002-03-01
err149
errOAAI
errMollenhauer, J; Aurich, ME; Zhong, Z; Muehleman, C; Cole, CC; Hasnah, M; Oltulu, O; Kuettner, KE; Margulis, A; Chapman, LD
err分享
err收藏
Diffraction enhanced x-ray imaging
err1999-01-01
err1.1K
errOAAI
errChapman, D; Thomlinson, W; Johnston, RE; Washburn, D; Pisano, E; Gmur, N; Zhong, Z; Menk, R; Arfelli, F; Sayers, D
err分享
err收藏
err分享
err收藏
Computed tomography of x-ray index of refraction using the diffraction enhanced imaging method
err2000-03-09
err270
PREAI
errDilmanian, FA; Zhong, Z; Ren, B; Wu, XY; Chapman, LD; Orion, I; Thomlinson, WC
err分享
err收藏
学者 查看更多内容