Optical surgical navigation system has been a hot research topic because of its high accuracy. This paper focuses on identifying and tracking multiple surgical instruments to meet the requirements of applying multiple surgical instruments in clinical medicine. The methods of instrument identification based on the marker's geometrical arrangement and instrument tracking based on markers' motion vector were applied in the proposed algorithm. The experiments of multiple instruments identification and tracking, the instruments' stability. the space distance and rotation of a pair of instruments at the same tracking time were performed to verify the proposed algorithm The stereoscopic camera is applied to capture images, and two 850 nm filters are added in front of the binocular camera. The tracking experiment shows that ten instruments can be fully and accurately identified, and then all of them can be quickly and accurately tracked at the same time. A pair of instruments is simultaneously measured in the stability test, such as the typical surgical instrument (TSI) and the miniature surgical instrument (MSI). The ranges of standard deviations (SD) of the stability test for the TSI in the X-, Y-, and Z-axes are from 0.016 nun to 0.127 mm, from 0.011 mm to 0.090 mm, and from 0.124 mm to 0.901 mm, respectively. And the ranges of SDs for the MSI's stability test are from 0.011 mm to 0.133 mm in the X-axis, from 0.010 mm to 0.106 mm in the Y-axis, and from 0.093 mm to 0.932 mm in the Z-axis. The sub-millimeter SDs show that the proposed algorithm has a high stability. Moreover, the space distance test and the rotation test were performed for simultaneously tracking TSI and MSI. All experimental results indicate the proposed algorithm is able to meet the clinical accuracy requirements. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
Keyword:
SYSTEM
ACCURACY
SURGERY

期刊

Optics Express 封面图
Optics Express
IF:
3.3
论文数:
6.1W
被引数:
14.3W

机构

C
Capital Medical University
学者数:
5.3W
论文数: 3.3W
被引数: 3.2W
B
Beijing University of Technology
学者数:
2.8W
论文数: 2.1W
被引数: 2.7W
C
chinese academy of sciences
学者数:
56.7W
论文数: 45.0W
被引数: 704
学者 查看更多机构
引用论文

引用论文

Failure modes of conducting yarns in electronic-textile applications
err2015-02-27
err0
PREAI
errMargreet de Kok; Hans de Vries; Katharine Pacheco; Gert van Heck
err分享
err收藏
Preliminary study of CVD diamond film to improve the performance of heat flux sensors for hypersonic experiments
err2005-03-01
err0
PREAI
errR.C. Follador; M.A.S. Minucci; P.G.P. Toro; V.J. Trava-Airoldi; N.G. Ferreira
err分享
err收藏
Advances in optical security systems
err2014-04-17
err473
PREAI
errChen, Wen; Javidi, Bahram; Chen, Xudong
err分享
err收藏
err分享
err收藏
err分享
err收藏
The Limits of Inference without Theory
err
IF0
err2013-04-26
err0
PREAI
errKenneth I. Wolpin
err分享
err收藏
学者 查看更多内容