Multisphere phantom and analysis algorithm for PET image quality assessment

delete2008-05-27
delete8
PRE
AI
J
Joshua M. Wilson *
T
Timothy G. Turkington
DOI:10.1088/0031-9155/53/12/013delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
PET image quality measurements of lesion detectability frequently use a small, radioactive sphere in a larger phantom. The typical analysis of a small single sphere in background has several shortcomings as a measure for detectability and quantitation: the measurement has low statistical power; the region of interest (ROI) is susceptible to large pixel-to-pixel fluctuations; only a single point in the axial and transaxial field of view is analyzed; background noise measurements in regions away from the signal sphere may bias the detectability measurement and user-placed ROIs can cause inconsistent measurements. For a more robust measurement and repeatable analysis of small lesion detectability in PET images, a multisphere phantom and analysis algorithm were developed. The multisphere phantom consists of a collection of 50 1.0-cm spheres, mounting rods and a gridded plate. A PET/CT study is presented where 29 spheres with a 4: 1 sphere-to-background radioactivity ratio were acquired for multiple frame durations and reconstructed. An analysis algorithm was implemented and applied to the acquired PET/CT that detects the contrast-enhanced spheres in a CT, places ROIs on the spheres and their respective proximal background, applies the ROIs to the PET and performs quantitation. Results are presented that show the impact of increasing number of signal spheres and of different background ROI placement methods on the image quality measurement. Increasing the number of spheres reduced the variability in the image quality measurements, but only up to a point, beyond which increasing the number of spheres did not considerably reduce the variability. A phantom with numerous spherical inserts increases several measurement aspects: the flexibility of sphere placement during setup, the number of radioactivity concentrations that can be used during a single study and the statistical power of measurements. Additionally, an automated algorithm that localizes spheres, places ROIs and performs quantitation will increase reliability and reproducibility of image quality assessment, in addition to simplifying the analysis.
Keyword:
PERFORMANCE
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Physics in Medicine and Biology 封面图
Physics in Medicine and Biology
IF:
3.4
论文数:
1.4W
被引数:
3.1W

机构

D
Duke University
学者数:
6.3W
论文数: 5.7W
被引数: 6.5W
引用论文

引用论文

Mechanical and Thermal Characterization of Natural Intralaminar Hybrid Composites Based on Sisal
err2020-04-09
err0
errOAAI
errAlexandre L. Pereira; Mariana D. Banea; Jorge S.S. Neto; Daniel K.K. Cavalcanti
err分享
err收藏
Noise characteristics of 3-D and 2-D PET images
err1998-01-01
err72
errOAAI
errPajevic, S; Daube-Witherspoon, ME; Bacharach, SL; Carson, RE
err分享
err收藏
没有更多内容