arrow
返回

NMR Spectral Alignment Utilizing a CryoEM Motion Correction Algorithm

delete2025-12-01
delete0
PRE
AI
C
Colin A. Hemme
O
Owen A. Warmuth
S
Songlin Wang
C
Christopher Williams
A
Alexander Thome
L
Leonard J. Mueller
C
Chad M. Rienstra
T
Timothy Grant *
DOI:10.1021/acs.analchem.5c02504delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
With recent advances in magic-angle spinning (MAS) solid-state NMR (SSNMR) resolution, precise spectral alignment has become a critical bottleneck in data processing workflows. While solution NMR employs deuterium lock systems, most SSNMR probes still lack this capability; though a lock corrects for magnet drift and instabilities, it is not alone sufficient to account for field gradients, sample temperature differences, and pulse sequence effects that can contribute to referencing errors among several data sets. These offsets become particularly problematic in the lengthy multidimensional experiments that provide the foundation for resonance assignment and structure determination procedures. Currently, researchers rely on manual alignment through visual peak inspection-a qualitative approach that often overemphasizes prominent, outlying peaks while overlooking subtle, global patterns. This subjective process becomes increasingly impractical for use cases with lower sensitivity, such as large proteins with thousands of peaks. To address these challenges, here we present Automated NMR Spectral Alignment (ANSA), a program that adapts cryo-electron microscopy motion correction principles to NMR spectroscopy. ANSA treats NMR spectra as images and applies cross-correlation functions to determine optimal alignment, improving cross-correlation scores from 0.33 to 1.00 in controlled tests and achieving 0.96 correlation in real-world applications with previously misaligned spectra. The algorithm successfully aligns spectra across varying experimental conditions, corrects shifts in long-duration experiments, and works with 2D and 3D data sets, with approaches that can be readily extended to additional dimensions. By eliminating human bias and providing objective, consistent spectral alignment, ANSA enhances scientific rigor, improves reproducibility between experiments, and enables automation of critical data processing steps. The software is freely available as an open-source tool, ready for integration into existing NMR workflows.
Keyword:
NUCLEAR-MAGNETIC-RESONANCE
SOLID-STATE NMR
BEAM-INDUCED MOTION
RESOLUTION
STANDARDIZATION
SPECTROSCOPY
SENSITIVITY
COMPLEX
EM

期刊

Analytical Chemistry 封面图
Analytical Chemistry
IF:
6.7
论文数:
4.7W
被引数:
15.9W

机构

University of Wisconsin System 封面图
University of Wisconsin System
学者数:
6.7W
论文数: 5.8W
被引数: 382
引用论文

引用论文

err分享
err收藏
Probe design for high sensitivity proton-detected solid-state NMR
err2025-09-01
err0
PREAI
errBorcik,Collin G.; Price,Lauren E.; Heinrich,John P.; Stringer,John A.; Rienstra,Chad M.
err分享
err收藏
High-resolution cryo-EM: the nuts and bolts
err2017-10-01
err55
PREAI
errElmlund, Dominika; Le, Sarah N.; Elmlund, Hans
err分享
err收藏
err1998-01-01
err0
PREAI
errJohn L. Markley; Ad Bax; Yoji Arata; C. W. Hilbers; Robert Kaptein; Brian D. Sykes; Peter E. Wright; Kurt Wüthrich
err分享
err收藏
Long-observation-window band-selective homonuclear decoupling: Increased sensitivity and resolution in solid-state NMR spectroscopy of proteins
err2013-11-01
err0
errOAAI
errJochem O. Struppe; Chen Yang; Yachong Wang; Roy V. Hernandez; Lisa M. Shamansky; Leonard J. Mueller
err分享
err收藏
Low power supercycled TPPM decoupling低功率超循环TPPM去耦
err2024-08-01
err0
PREAI
errRajat Garg; Barry DeZonia; Alexander L. Paterson; Chad M. Rienstra
err分享
err收藏
err
IF0
err
err0
errOAAI
err
err分享
err收藏
学者 查看更多内容