arrow
返回

Open-Source, Step-Counting Algorithm for Smartphone Data Collected in Clinical and Nonclinical Settings: Algorithm Development and Validation Study

delete2023-11-15
delete4
delete
OA
AI
M
Marcin Strączkiewicz *
N
Nancy L. Keating
E
Embree Thompson
U
Ursula A. Matulonis
S
Susana M. Campos
A
Alexi A. Wright
J
Jukka‐Pekka Onnela
DOI:10.2196/47646delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Background: Step counts are increasingly used in public health and clinical research to assess well-being, lifestyle, and health status. However, estimating step counts using commercial activity trackers has several limitations, including a lack of reproducibility, generalizability, and scalability. Smartphones are a potentially promising alternative, but their step-counting algorithms require robust validation that accounts for temporal sensor body location, individual gait characteristics, and heterogeneous health states.Objective: Our goal was to evaluate an open-source, step-counting method for smartphones under various measurement conditions against step counts estimated from data collected simultaneously from different body locations (cross-body validation), manually ascertained ground truth (visually assessed validation), and step counts from a commercial activity tracker (Fitbit Charge 2) in patients with advanced cancer (commercial wearable validation).Methods: We used 8 independent data sets collected in controlled, semicontrolled, and free-living environments with different devices (primarily Android smartphones and wearable accelerometers) carried at typical body locations. A total of 5 data sets (n=103) were used for cross-body validation, 2 data sets (n=107) for visually assessed validation, and 1 data set (n=45) was used for commercial wearable validation. In each scenario, step counts were estimated using a previously published step-counting method for smartphones that uses raw subsecond-level accelerometer data. We calculated the mean bias and limits of agreement (LoA) between step count estimates and validation criteria using Bland-Altman analysis.Results: In the cross-body validation data sets, participants performed 751.7 (SD 581.2) steps, and the mean bias was -7.2 (LoA -47.6, 33.3) steps, or -0.5%. In the visually assessed validation data sets, the ground truth step count was 367.4 (SD 359.4) steps, while the mean bias was -0.4 (LoA -75.2, 74.3) steps, or 0.1%. In the commercial wearable validation data set, Fitbit devices indicated mean step counts of 1931.2 (SD 2338.4), while the calculated bias was equal to -67.1 (LoA -603.8, 469.7) steps, or a difference of 3.4%.Conclusions: This study demonstrates that our open-source, step-counting method for smartphone data provides reliable step counts across sensor locations, measurement scenarios, and populations, including healthy adults and patients with cancer.
Keyword:
accelerometer
cancer
open-source
smartphone
step count
validation
wearable

期刊

JMIR Cancer 封面图
JMIR Cancer
IF:
2.7
论文数:
340
被引数:
988

机构

H
Harvard University
学者数:
26.5W
论文数: 22.0W
被引数: 28.7W
H
Harvard T.H. Chan School of Public Health
学者数:
1.6W
论文数: 1.4W
被引数: 36
H
Harvard Medical School
学者数:
6.5W
论文数: 4.8W
被引数: 91
学者 查看更多机构
引用论文

引用论文

An ultra-low noise MEMS accelerometer for seismic imaging
err2011-10-01
err0
PREAI
errDonald J. Milligan; Brian D. Homeijer; Robert G. Walmsley
err分享
err收藏
err分享
err收藏
Pharmacokinetics of Amikacin in Neonates
err1993-07-01
err0
PREAI
errEzio Maria Padovani; Carola Pistolesi; Vassilios Fanos; Andrea Messori; Nello Martini
err分享
err收藏
Acceptance of Commercially Available Wearable Activity Trackers Among Adults Aged Over 50 and With Chronic Illness: A Mixed-Methods Evaluation
err2016-01-27
err295
errOAAI
errMercer, Kathryn; Giangregorio, Lora; Schneider, Eric; Chilana, Parmit; Li, Melissa; Grindrod, Kelly
err分享
err收藏
err分享
err收藏
Walking Recognition in Mobile Devices
errSENSORS
IF3.5
err2020-02-21
err15
errOAAI
errCasado, Fernando E.; Rodriguez, German; Iglesias, Roberto; Regueiro, Carlos, V; Barro, Senen; Canedo-Rodriguez, Adrian
err分享
err收藏
Structural integrity of rotator cuff at 16 years following repair: good long-term outcomes despite recurrent tears
err2017-11-10
err0
errOAAI
errRobert S. J. Elliott; Yi-Jia Lim; Jennifer Coghlan; John Troupis; Simon Bell
err分享
err收藏
学者 查看更多内容