arrow
返回

Optical angle and visuospatial ability affect basic laparoscopic simulator task performance

delete2024-04-01
delete0
delete
OA
AI
B
Bas Kengen *
W
Willem B. Verwey
H
Harry van Goor
J
Jan‐Maarten Luursema
DOI:10.1016/j.apergo.2023.104210delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Surgical trainees show decreased performance during laparoscopic surgery when the laparoscope (camera) is not aligned with their line of sight towards the operating area. In this study we investigate the influence of visuospatial ability on laparoscopic simulator performance under such non-zero optical angles. Novices were invited to participate in a laparoscopic training session. After completing a visuospatial ability assessment, they performed a simplified laparoscopic task on an in-house developed laparoscopic simulator under eight different optical angles ranging between 0 degrees and 315 +/- in steps of 45 +/-. Data-analysis showed decreased performance under all non-zero optical angles for task duration (mean difference between 1506 and 5049 ms, standard error between 499 and 507, p < .05) and for accuracy under optical angles greater than +/- 45 +/- (mean difference between 1.48 and 2.11, standard error 0.32, p < .01). Performance-zones were identified for various optical angle ranges and differed for task duration and accuracy. Participants of high visuospatial ability performed significantly better under non-zero angles for accuracy compared to participants of low visuospatial ability (mean difference 0.95, standard error 0.34, p < .01), except for the 180 optical angle (no difference).
Keyword:
Visuospatial ability
Laparoscopy
Training
Optical angle
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Applied Ergonomics 封面图
Applied Ergonomics
IF:
3.4
论文数:
4.9K
被引数:
1.2W

机构

U
university of twente
学者数:
1.5W
论文数: 1.4W
被引数: 9
R
Radboud University Nijmegen
学者数:
4.4W
论文数: 3.4W
被引数: 5.4W
引用论文

引用论文

err
IF0
err
err0
PREAI
err
err分享
err收藏
err分享
err收藏
Nrf2 Protein Serum Concentration in Human CKD Shows a Biphasic Behavior
err2023-04-14
err0
errOAAI
errMarianne Rasmussen; Kristian Horsman Hansen; Alexandra Scholze
err分享
err收藏
Bubble Test and Carotid Ultrasound to Guide Indication of Transesophageal Echocardiography in Young Patients With Stroke
err2022-03-04
err0
errOAAI
errErnst Mayerhofer; Dirk Kanz; Brigitte Guschlbauer; Christopher D. Anderson; Alexander Asmussen; Sebastian Grundmann; Christoph Strecker; Andreas Harloff
err分享
err收藏
Experienced laparoscopic surgeons are automated to the fulcrum effect: An ergonomic demonstration
errENDOSCOPY
IF12.8
err1999-06-01
err97
PREAI
errCrothers, IR; Gallagher, AG; McClure, N; James, DTD; McGuigan, J
err分享
err收藏
学者 查看更多内容