arrow
返回

Optical Parameter Decoupling and Optimization for Elliptically Polarized Atomic Magnetometer

delete2024-01-01
delete8
PRE
AI
Y
Yifan Yan
S
Shaowen Zhang
Z
Zehua Liu
D
Di Zhan
Z
Ziao Liu
X
Xiaoyu Li
Y
Ying Zhou
陆
陆吉玺 (Jixi Lu) *
DOI:10.1109/TIM.2023.3343783delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Elliptically polarized atomic magnetometers (AMs) offer high sensitivity and compactness by using a single laser beam to polarize atoms and detect optical rotation angles. However, their sensitivity advantage over optical absorption-based AMs has not been sufficiently demonstrated. This is because the optical parameters significantly affect the pumping and probing processes, leading to parameter coupling when both processes are optimized simultaneously. Such coupling presents a considerable challenge for achieving simultaneous parameter optimization, ultimately limiting the achievable sensitivity. In this study, we developed a modified input-output model for a magnetometer, based on which an optical parameter decoupling and optimization method is proposed. Our method enables us to obtain the optimal optical parameters simultaneously, including the ellipticity, intensity, and frequency of light. Consequently, a sensitivity of 6 fT/Hz(1/2) was achieved using a 4 x 4 x 4 mm(3) Rb-87 vapor cell (an effective volume of 0.027 cm(3)). This work offers an efficient strategy to achieve higher sensitivity using single-beam miniaturized AMs, contributing significantly to promote biomagnetism research.
Keyword:
Optical pumping
Sensitivity
Optical polarization
Atom optics
Optical sensors
Laser beams
Biomedical optical imaging
Atomic magnetometers (AMs)
biomagnetism
decoupling and optimization
elliptically polarized light
spin-exchange relaxation free (SERF)

期刊

IEEE Transactions on Instrumentation and Measurement 封面图
IEEE Transactions on Instrumentation and Measurement
IF:
5.9
论文数:
2.0W
被引数:
5.8W

机构

B
Beihang University
学者数:
5.2W
论文数: 4.1W
被引数: 37
引用论文

引用论文

err
IF0
err
err0
errOAAI
err
err分享
err收藏
The results of pollicization for congenital thumb hypoplasia
err2014-05-23
err0
PREAI
errM. A. Tonkin; D. E. Boyce; P. P. Fleming; S. L. Filan; N. Vigna
err分享
err收藏
External Dose Estimation for Nuclear Worker Studies
err2006-07-01
err0
PREAI
errE. S. Gilbert; I. Thierry-Chef; E. Cardis; J. J. Fix; M. Marshall
err分享
err收藏
err
IF0
err
err0
PREAI
err
err分享
err收藏
Three-axis closed-loop optically pumped magnetometer operated in the SERF regime
err2022-05-11
err63
errOAAI
errYan, Yeguang; Lu, Jixi; Zhang, Shaowen; Lu, Fei; Yin, Kaifeng; Wang, Kun; Zhou, Binquan; Liu, Gang
err分享
err收藏
Subpicotesla atomic magnetometry with a microfabricated vapour cell
err2007-11-01
err368
PREAI
errShah, Vishal; Knappe, Svenja; Schwindt, Peter D. D.; Kitching, John
err分享
err收藏
A microfabricated optically-pumped magnetic gradiometer
err2017-01-18
err175
errOAAI
errSheng, D.; Perry, A. R.; Krzyzewski, S. P.; Geller, S.; Kitching, J.; Knappe, S.
err分享
err收藏
Third‐order depositional sequences reflecting Milankovitch cyclicity
err2002-01-19
err0
errOAAI
errAndré Strasser; Heiko Hillgärtner; Wolfgang Hug; Bernard Pittet
err分享
err收藏
学者 查看更多内容