返回
Optimal stratification improves efficiency in fixed-bed separation
DOI:10.1016/j.seppur.2024.131127.png)
摘要
En 中文
Several studies show that stratified fixed-bed separation columns have the potential to improve the process performance in various applications compared to homogeneous columns. However, the actual target for designing the stratification remained unclear. In a previous contribution, we developed a model-based design strategy based on an optimal control approach. To study the implication of that approach, we here performed experiments with optimally designed stratified activated carbon adsorption columns to remove phenol from water. Two different case studies were investigated. In the first case study, the optimal stratified column improved the breakthrough curve by 48.26% compared to a homogeneous column using the mean particle diameter as a constraint. In the second case study, the optimal stratified column achieved a 51.87% sharper breakthrough curve compared to a non-optimized stratified column using the pressure drop as a constraint. The presented technique is not limited to adsorption columns but holds implications for further unit operations, such as liquid chromatography.
Keyword:
Model-based design
Optimal control theory
Stratified columns
Fixed-bed separation
Adsorption columns
Activated carbon
Phenol removal
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
9
论文数:
3.0W
被引数:
12.1W
机构
引用论文
Impact of particle size gradients on the apparent efficiency of chromatographic columns粒度梯度对色谱柱表观效率的影响
Considering the selectivity of pore size gradient size exclusion chromatography columns考虑孔径梯度尺寸排阻色谱柱的选择性