arrow
返回

Optimized Parallel Imaging for Dynamic PC-MRI with Multidirectional Velocity Encoding

delete2010-05-17
delete17
PRE
AI
H
Hsu‐Hsia Peng
S
Simon Bauer
T
Teng‐Yi Huang
H
Hsiao‐Wen Chung
J
Jürgen Hennig
B
Bernd Jung
M
Michael Markl *
DOI:10.1002/mrm.22432delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Phase contrast MRI with multidirectional velocity encoding requires multiple acquisitions of the same k-space lines to encode the underlying velocities, which can considerably lengthen the total scan time. To reduce scan time, parallel imaging is often applied. In dynamic phase contrast MRI using standard generalized autocalibrating partially parallel acquisitions (GRAPPA), several central k-spaces for autocalibration of the reconstruction (autocalibrating signal lines (ACS)) are typically acquired, separately for each velocity direction and each cardiac timeframe, for calculating the reconstruction weights. To further accelerate data acquisition, we developed two methods, which calculated weights with a substantially reduced number of ACSI lines. The effects on image quality and flow quantification were compared to fully sampled data, standard GRAPPA, and time-interleaved sampling scheme in combination with generalized autocalibrating partially parallel acquisitions (TGRAPPA). The results show that the two proposed methods can clearly improve scan efficiency while maintaining image quality and accuracy of measured flow or myocardial tissue velocities. Compared to TGRAPPA, the proposed methods were more accurate in evaluating flow velocity. In conclusion, the proposed reconstruction strategies are promising for dynamic multidirectionally encoded acquisitions and can easily be implemented using the standard GRAPPA reconstruction algorithm. Magn Reson Med 64:472-480, 2010. (C) 2010 Wiley-Liss, Inc.
Keyword:
parallel imaging
undersampling
GRAPPA
dynamic phase contrast imaging
velocity
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Magnetic Resonance in Medicine 封面图
Magnetic Resonance in Medicine
IF:
3
论文数:
1.2W
被引数:
3.1W

机构

N
National Tsing Hua University
学者数:
1.6W
论文数: 1.4W
被引数: 1.7W
N
National Taiwan University
学者数:
4.7W
论文数: 4.2W
被引数: 3.6W
N
national taiwan university of science & technology
学者数:
8.8K
论文数: 8.7K
被引数: 9
U
University of Freiburg
学者数:
3.3W
论文数: 2.4W
被引数: 3.4W
学者 查看更多机构
引用论文

引用论文

err分享
err收藏
Quantitative 2D and 3D Phase Contrast MRI: Optimized Analysis of Blood Flow and Vessel Wall Parameters
err2008-10-27
err431
PREAI
errStalder, A. F.; Russe, M. F.; Frydrychowicz, A.; Bock, J.; Hennig, J.; Markl, M.
err分享
err收藏
RENAL-ARTERY BLOOD-FLOW - QUANTITATION WITH PHASE-CONTRAST MR-IMAGING WITH AND WITHOUT BREATH-HOLDING
errRADIOLOGY
IF15.2
err1994-02-01
err133
PREAI
errDEBATIN, JF; TING, RH; WEGMULLER, H; SOMMER, FG; FREDRICKSON, JO; BROSNAN, TJ; BOWMAN, BS; MYERS, BD; HERFKENS, RJ; PELC, NJ
err分享
err收藏
学者 查看更多内容