返回
OSI-flex: optimization-based shearing interferometry for joint phase and shear estimation using a flexible open-source framework
DOI:10.1088/2515-7647/ae3504.png)
摘要
En 中文
Shearing interferometry is a common-path quantitative phase imaging technique in which an object beam interferes with a laterally shifted replica of itself, providing high temporal stability, reduced sensitivity to environmental noise, compact design, and compatibility with partially coherent illumination that suppresses coherence-related artifacts. Its principal limitation, however, is that it yields only sheared phase-difference measurements rather than the absolute phase, thereby requiring an additional reconstruction step. In this work, we introduce OSI-flex, a flexible, open-source computational framework for quantitative phase reconstruction from sheared phase-difference measurements. The method leverages modern machine learning tools, namely automatic differentiation, and the advanced adaptive moment estimation optimizer. The method simultaneously refines the phase distribution and estimates the shear values, enabling adaptation to experimental conditions where the shear cannot be precisely determined. Because defining shear value is inherently difficult in most systems, yet crucial for effective phase reconstruction, this joint optimization leads to robust and reliable phase retrieval. The proposed OSI-flex framework is highly versatile, supporting arbitrary numbers, magnitudes, and orientations of shear vectors. While optimal reconstruction is achieved with two orthogonal shear directions, the inclusion of regularization—specifically total variation minimization and sign constraint—enables OSI-flex to remain effective with nonorthogonal or even single-shear measurements. Moreover, the algorithm accommodates a wide range of shear magnitudes, from subpixel shifts (differential configuration) to several dozen pixels (semi-total shear configuration). Validation with simulations and experimental data confirms quantitative accuracy on calibrated phase objects and demonstrates robustness with 3D-printed cell phantom and follicular thyroid cells.
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
J
IF:
0
论文数:
66
被引数:
0
机构
引用论文
Quantitative 3D refractive index tomography of opaque samples in epi-modeepi模式下不透明样品的定量3D折射率层析成像
OPTICA
IF8.5
Polarization Gratings Aided Common-Path Hilbert Holotomography for Label-Free Lipid Droplets Content Assay偏振光栅辅助的同轴希尔伯特全息层析术用于无标记脂滴含量分析

