arrow
返回

Parallel feature based calibration method for a trinocular vision sensor

delete2020-06-26
delete7
delete
OA
AI
M
Mingwei Shao *
M
Mengjie Hu
DOI:10.1364/OE.393012delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
In this paper, a new method to calibrate a trinocular vision sensor is presented. A planar target with several parallel lines is utilized. The trifocal tensor of three image planes can be calculated out according to line correspondences. Compatible essential matrix between each two cameras can be obtained. Then, rotation matrix and translation matrix can be deduced base on singular value decomposition of their corresponding essential matrix. In our proposed calibration method, image rectification is carried out to remove perspective distortion. As the feature utilized is straight line, precise point to point correspondence is not necessary. Experimental results show that our proposed calibration method can obtain precise results. Moreover, the trifocal tensor can also give a strict constraint for feature matching as descripted in our previous work. Root mean square error of measured distances is 0.029 mm with regards to the view field of about 250x250 mm. As parallel feature exists widely in natural scene, our calibration method also provides a new approach for self-calibration of a trinocular vision sensor. (C) 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
Keyword:
MULTI-CAMERA

期刊

Optics Express 封面图
Optics Express
IF:
3.3
论文数:
6.1W
被引数:
14.3W

机构

Q
Qingdao University of Technology
学者数:
8.0K
论文数: 5.2K
被引数: 7.1K
B
beijing university of posts & telecommunications
学者数:
1.4W
论文数: 1.2W
被引数: 9
引用论文

引用论文

Improved separated-parameter calibration method for binocular vision measurements with a large field of view
err2020-01-22
err27
errOAAI
errZhang, Yang; Liu, Wei; Wang, Fuji; Lu, Yongkang; Wang, Wenqi; Yang, Fan; Jia, Zhenyuan
err分享
err收藏
A calibration method for stereo vision sensor with large FOV based on 1D targets
err2011-11-01
err49
PREAI
errSun, Junhua; Liu, Qianzhe; Liu, Zhen; Zhang, Guangjun
err分享
err收藏
Ulcère chronique sous hydroxyurée : interrompre le traitement ?
err2009-03-01
err0
PREAI
errU. Michon-Pasturel; I. Lazareth; A. Bouchareb; S. Bonhomme; P. Priollet
err分享
err收藏
Precise calibration of binocular vision system used for vision measurement
err2014-04-08
err107
errOAAI
errCui, Yi; Zhou, Fuqiang; Wang, Yexin; Liu, Liu; Gao, He
err分享
err收藏
Calibration of a trinocular system formed with wide angle lens cameras
err2012-11-29
err16
errOAAI
errRicolfe-Viala, Carlos; Sanchez-Salmeron, Antonio-Jose; Valera, Angel
err分享
err收藏
err分享
err收藏
学者 查看更多内容