arrow
返回

Passive Mixing inside Microdroplets

delete2018-04-01
delete59
delete
OA
AI
C
Chengmin Chen
Y
Yingjie Zhao
J
Jianmei Wang
朱
朱平安 (Pingan Zhu)
Y
Ye Tian
M
Min Xu
王
王丽邱 (Liqiu Wang)
X
Xiaowen Huang *
DOI:10.3390/mi9040160delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Droplet-based micromixers are essential units in many microfluidic devices for widespread applications, such as diagnostics and synthesis. The mixers can be either passive or active. When compared to active methods, the passive mixer is widely used because it does not require extra energy input apart from the pump drive. In recent years, several passive droplet-based mixers were developed, where mixing was characterized by both experiments and simulation. A unified physical understanding of both experimental processes and simulation models is beneficial for effectively developing new and efficient mixing techniques. This review covers the state-of-the-art passive droplet-based micromixers in microfluidics, which mainly focuses on three aspects: (1) Mixing parameters and analysis method; (2) Typical mixing element designs and the mixing characters in experiments; and, (3) Comprehensive introduction of numerical models used in microfluidic flow and diffusion.
Keyword:
passive mixing
microdroplets
multiphase
simulation model
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Micromachines 封面图
Micromachines
IF:
3
论文数:
1.4W
被引数:
2.9W

机构

Q
Qilu University of Technology
学者数:
1.1W
论文数: 8.9K
被引数: 16
U
University of Hong Kong
学者数:
4.1W
论文数: 3.9W
被引数: 10.1W
引用论文

引用论文

Transferred Donor-Derived Virus Specific CD8+ T Cells That Have Been Transduced to Express a WT1-Specific T Cell Receptor Can Persist and Provide Anti-Leukemic Activity in AML Patients Post-Transplant
err2014-12-06
err0
PREAI
errMerav Bar; Aude G. Chapuis; Thomas M Schmitt; Hieu Nguyen; Natalie A Duerkopp; Mark F Tom; Felecia D Wagener; Colette N Chaney; Kieu-Thu Bui; Shelly Heimfeld; Philip D. Greenberg
err分享
err收藏
err分享
err收藏
A fast and efficient microfluidic system for highly selective one-to-one droplet fusion
err2009-01-01
err175
PREAI
errMazutis, Linas; Baret, Jean-Christophe; Griffiths, Andrew D.
err分享
err收藏
Conglobatins B–E: cytotoxic analogues of the C2-symmetric macrodiolide conglobatin
err2020-06-17
err0
errOAAI
errHeather J. Lacey; Thomas J. Booth; Daniel Vuong; Peter J. Rutledge; Ernest Lacey; Yit-Heng Chooi; Andrew M. Piggott
err分享
err收藏
err分享
err收藏
err分享
err收藏
P1.05-026 High Resolution Metabolomics on Exhaled Breath Condensate to Discover Lung Cancer's Biomarker
err2017-01-01
err0
errOAAI
errChang Young Park; Adnan Khan; Aryo Pamungkas; Eun Jung Sim; Kyung Ho Kang; Sung Yong Lee; Youngja Hwang Park
err分享
err收藏
学者 查看更多内容