Phase-contrast digital tomosynthesis

delete2011-04-26
delete19
PRE
AI
J
Jeffrey C. Hammonds *
R
Ronald R. Price
E
Edwin F. Donnelly
D
David R. Pickens
DOI:10.1118/1.3574871delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Purpose: Phase-contrast (PC) edge enhancement occurs at the boundary between different tissues and is an interference effect that results from the differential phase-shifts that the x-rays acquire while traversing the two tissues. While observable in planar phase-contrast radiographs, the impact of digital tomosynthesis on this edge enhancement effect has not been previously reported. The purpose of this work is to demonstrate: (1) that phase-contrast digital tomosynthesis (PC-DTS) is possible with a conventional x-ray source, (2) that the reconstructed tomosynthesis images demonstrate and retain edge enhancement as compared to planar phase-contrast radiographs and (3) tomosynthesis improves object contrast by reducing the effects of superimposed structures. Methods: An unmodified, commercially available cabinet x-ray system (Faxitron LX-60) was used. The system contains a tungsten anode x-ray tube that was operated at 24 kVp and 3 mAs for each PC radiographic image taken, with a nominal focal spot size of 0.010 mm. The digital detector uses CsI/CMOS with a pixel size of 0.054 mm x 0.054 mm. Objects to be imaged were attached to a computer-controlled rotating motor and are rotated +/- 25 degrees about a central position in one degree increments. At each increment, three phase-contrast radiographs are taken and then averaged to reduce the effect of noise. These planar images are then used to reconstruct a series of 56 longitudinal tomographic images with an image offset increment of about 0.7 mm. Results: Tomographic z-plane resolution was measured to be approximately 4 mm. When compared to planar PC images, the tomosynthesis images were shown to retain the PC boundary edge enhancement in addition to an improvement in object contrast. Conclusions: Our work demonstrates that PC digital tomosynthesis retains the edge-enhancement observed in planar PC radiograph and further improves soft-tissue conspicuity by reducing the effects of superimposed tissue structure. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3574871]
Keyword:
phase-contrast
digital tomosynthesis
cabinet x-ray system

期刊

Medical Physics 封面图
Medical Physics
IF:
3.2
论文数:
3.7W
被引数:
3.2W

机构

V
vanderbilt university
学者数:
5.1W
论文数: 4.1W
被引数: 59
引用论文

引用论文

Mammography with synchrotron radiation: Phase-detection techniques
errRADIOLOGY
IF15.2
err2000-04-01
err288
PREAI
errArfelli, F; Bonvicini, V; Bravin, A; Cantatore, G; Castelli, E; Dalla Palma, L; Di Michiel, M; Fabrizioli, M; Longo, R; Menk, RH; Olivo, A; Pani, S; Pontoni, D; Poropat, P; Prest, M; Rashevsky, A; Ratti, M; Rigon, L; Tromba, G; Vacchi, A; Vallazza, E; Zanconati, F
err分享
err收藏
Low-dose phase contrast x-ray medical imaging
err1999-01-01
err248
PREAI
errArfelli, F; Assante, M; Bonvicini, V; Bravin, A; Cantatore, G; Castelli, E; Dalla Palma, L; Di Michiel, M; Longo, R; Olivo, A; Pani, S; Pontoni, D; Poropat, P; Prest, M; Rashevsky, A; Tromba, G; Vacchi, A; Vallazza, E; Zanconati, F
err分享
err收藏
Digital Tomosynthesis in breast imaging
errRADIOLOGY
IF15.2
err1997-11-01
err785
PREAI
errNiklason, LT; Christian, BT; Niklason, LE; Kopans, DB; Castleberry, DE; OpsahlOng, BH; Landberg, CE; Slanetz, PJ; Giardino, AA; Moore, R; Albagli, D; DeJule, MC; Fitzgerald, PF; Fobare, DF; Giambattista, BW; Kwasnick, RF; Liu, JQ; Lubowski, SJ; Possin, GE; Richotte, JF; Wei, CY; Wirth, RF
err分享
err收藏
学者 查看更多内容