Phase-contrast digital tomosynthesis
DOI:10.1118/1.3574871.png)
摘要
En 中文
Purpose: Phase-contrast (PC) edge enhancement occurs at the boundary between different tissues and is an interference effect that results from the differential phase-shifts that the x-rays acquire while traversing the two tissues. While observable in planar phase-contrast radiographs, the impact of digital tomosynthesis on this edge enhancement effect has not been previously reported. The purpose of this work is to demonstrate: (1) that phase-contrast digital tomosynthesis (PC-DTS) is possible with a conventional x-ray source, (2) that the reconstructed tomosynthesis images demonstrate and retain edge enhancement as compared to planar phase-contrast radiographs and (3) tomosynthesis improves object contrast by reducing the effects of superimposed structures. Methods: An unmodified, commercially available cabinet x-ray system (Faxitron LX-60) was used. The system contains a tungsten anode x-ray tube that was operated at 24 kVp and 3 mAs for each PC radiographic image taken, with a nominal focal spot size of 0.010 mm. The digital detector uses CsI/CMOS with a pixel size of 0.054 mm x 0.054 mm. Objects to be imaged were attached to a computer-controlled rotating motor and are rotated +/- 25 degrees about a central position in one degree increments. At each increment, three phase-contrast radiographs are taken and then averaged to reduce the effect of noise. These planar images are then used to reconstruct a series of 56 longitudinal tomographic images with an image offset increment of about 0.7 mm. Results: Tomographic z-plane resolution was measured to be approximately 4 mm. When compared to planar PC images, the tomosynthesis images were shown to retain the PC boundary edge enhancement in addition to an improvement in object contrast. Conclusions: Our work demonstrates that PC digital tomosynthesis retains the edge-enhancement observed in planar PC radiograph and further improves soft-tissue conspicuity by reducing the effects of superimposed tissue structure. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3574871]
Keyword:
phase-contrast
digital tomosynthesis
cabinet x-ray system
期刊
IF:
3.2
论文数:
3.7W
被引数:
3.2W
机构
引用论文
Accuracy of CT-based thickness measurement of thin structures: Modeling of limited spatial resolution in all three dimensions基于CT的薄结构厚度测量的准确性: 在所有三个维度上的有限空间分辨率的建模
MEDICAL PHYSICS
IF3.2
Employees’ perceptions of barriers to participation in training and development in small engineering businesses员工对参与培训与发展的障碍感知(在小型工程企业中)