arrow
返回

Point-source extraction with MOPEX

delete2005-10-01
delete285
delete
OA
AI
M
Makovoz, D
M
Marleau, FR
DOI:10.1086/432977delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
MOPEX (Mosaicking and Point-source Extraction) is a package developed at the Spitzer Science Center for astronomical image processing. We report on the point-source extraction capabilities of MOPEX. Point-source extraction is implemented as a two-step process: point-source detection and profile fitting. Nonlinear matched filtering of input images can be performed optionally to increase the signal-to-noise ratio and improve detection of faint point sources. Point response function (PRF) fitting of point sources produces the final point-source list, which includes the fluxes and improved positions of the point sources, along with other parameters characterizing the fit. Passive and active deblending allows for successful fitting of confused point sources. Aperture photometry can also be computed for every extracted point source for an unlimited number of aperture sizes. The PRF is estimated directly from the input images. The implementation of efficient methods of background and noise estimation and a modified simplex algorithm contribute to the computational efficiency of MOPEX. The package is implemented as a loosely connected set of Perl scripts, each script running a number of modules written in C/C++. Input parameter setting is done through name lists, ASCII configuration files. We present applications of point-source extraction to the mosaic images taken at 24 and 70 mm with the Multiband Imaging Photometer (MIPS) as part of the Spitzer extragalactic First Look Survey, and to a Digital Sky Survey image. Completeness and reliability of point-source extraction is computed using simulated data.
Keyword:
PHOTOMETRY
PROGRAM

期刊

Publications of the Astronomical Society of the Pacific 封面图
Publications of the Astronomical Society of the Pacific
IF:
7.7
论文数:
4.0K
被引数:
1.8W

机构

暂无机构信息
引用论文

引用论文

Extragalactic source counts at 24 microns in the Spitzer First Look Survey
err2004-09-01
err66
errOAAI
errMarleau, FR; Fadda, D; Storrie-Lombardi, LJ; Helou, G; Makovoz, D; Frayer, DT; Yan, L; Appleton, PN; Armus, L; Chapman, S; Choi, PI; Fang, F; Heinrichsen, I; Im, M; Lacy, M; Shupe, D; Soifer, BT; Squires, G; Surace, J; Teplitz, HI; Wilson, G
err分享
err收藏
err分享
err收藏
Safety and Efficacy of Same-Session Bilateral Ureteroscopy
err2003-12-01
err0
errOAAI
errBrent K. Hollenbeck; Timothy G. Schuster; Gary J. Faerber; J. Stuart Wolf
err分享
err收藏
没有更多内容