arrow
返回

Portable low-power electronic interface for explosive detection using microcantilevers

delete2014-09-01
delete24
delete
OA
AI
D
D. García-Romeo *
I
Ismael Pellejero
M
Miguel Urbiztondo
J
J. Sesé
M
M.P. Pina
P
P.A. Martínez
B
B. Calvo
N
N. Medrano
DOI:10.1016/j.snb.2014.04.038delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Microcantilevers have been recently revealed as a highly effective technique for gas detection at trace level when acting as chemical sensors. However, an important milestone still remains to achieve a full-scale development in commercial applications: the cumbersome systems traditionally used to read-out its responses. To accomplish this, a portable low-power electronic interface, based on an analog lock-in amplifier processing square signals, which is fully capable of creating the excitation signal as well as obtaining the response values from resonating microcantilevers functionalized with zeolite based coatings has been herein attempted. The so obtained read-out results are in good agreement with the commercial lock-in amplifier's measurements, demonstrating the accuracy and reliability of the electronic interface. Finally, its performance has been validated for 2-nitrotoluene (o-MNT) detection at ppm V level, as an example of an explosive-related molecule, with BEA zeolite coated microcantilevers. Theoretical limit of detection (LOD) values below 100 ppb have been obtained for Co exchanged BEA modified sensors. (C) 2014 Elsevier B.V. All rights reserved.
Keyword:
Microcantilevers
Gas sensing
Zeolites
Nanoporous coating
Explosives
Portable lock-in amplifier
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Sensors and Actuators B-Chemical 封面图
Sensors and Actuators B-Chemical
IF:
7.7
论文数:
3.4W
被引数:
12.6W

机构

U
University of Zaragoza
学者数:
1.5W
论文数: 1.2W
被引数: 14
引用论文

引用论文

err
IF0
err
err0
PREAI
err
err分享
err收藏
err分享
err收藏
err分享
err收藏
err分享
err收藏
err分享
err收藏
A microfluidic based differential plasmon resonance sensor
err2011-12-01
err6
PREAI
errOkan, Melih; Balci, Osman; Kocabas, Coskun
err分享
err收藏
Graphene Oxide-Based Homogeneous Fluorescence Sensor for Multiplex Determination of Various Targets by a Multifunctional Aptamer
err2015-05-05
err0
PREAI
errXia Chen; Huina Zhou; Niu Zhai; Pingping Liu; Qiansi Chen; Lifeng Jin; Qingxia Zheng
err分享
err收藏
Low-voltage low-power integrated analog lock-in amplifier for gas sensor applications用于气体传感器应用的低电压低功耗集成模拟锁相放大器
err2010-02-17
err71
PREAI
errD'Amico, A.; De Marcellis, A.; Di Carlo, C.; Di Natale, C.; Ferri, G.; Martinelli, E.; Paolesse, R.; Stornelli, V.
err分享
err收藏
学者 查看更多内容