Pre-excitation gradients for eddy current nulled convex optimized diffusion encoding (Pre-ENCODE)

delete2024-03-19
delete0
PRE
AI
M
Matthew J. Middione
M
Michael Loecher
X
Xiaozhi Cao
K
Kawin Setsompop
D
Daniel B. Ennis *
DOI:10.1002/mrm.30068delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
PurposeTo evaluate the use of pre-excitation gradients for eddy current-nulled convex optimized diffusion encoding (Pre-ENCODE) to mitigate eddy current-induced image distortions in diffusion-weighted MRI (DWI).MethodsDWI sequences using monopolar (MONO), ENCODE, and Pre-ENCODE were evaluated in terms of the minimum achievable echo time (TE min$$ {}_{\mathrm{min}} $$) and eddy current-induced image distortions using simulations, phantom experiments, and in vivo DWI in volunteers (N=6$$ N=6 $$).ResultsPre-ENCODE provided a shorter TE min$$ {}_{\mathrm{min}} $$ than MONO (71.0 +/-$$ \pm $$ 17.7ms vs. 77.6 +/-$$ \pm $$ 22.9ms) and ENCODE (71.0 +/-$$ \pm $$ 17.7ms vs. 86.2 +/-$$ \pm $$ 14.2ms) in 100%$$ \% $$ of the simulated cases for a commercial 3T MRI system with b-values ranging from 500 to 3000 s/mm 2$$ {}<^>2 $$ and in-plane spatial resolutions ranging from 1.0 to 3.0mm 2$$ {}<^>2 $$. Image distortion was estimated by intravoxel signal variance between diffusion encoding directions near the phantom edges and was significantly lower with Pre-ENCODE than with MONO (10.1%$$ \% $$ vs. 22.7%$$ \% $$, p=6-5$$ p={6}<^>{-5} $$) and comparable to ENCODE (10.1%$$ \% $$ vs. 10.4%$$ \% $$, p=0.12$$ p=0.12 $$). In vivo measurements of apparent diffusion coefficients were similar in global brain pixels (0.37 [0.28,1.45]x10-3$$ \times 1{0}<^>{-3} $$ mm 2$$ {}<^>2 $$/s vs. 0.38 [0.28,1.45]x10-3$$ \times 1{0}<^>{-3} $$mm 2$$ {}<^>2 $$/s, p=0.25$$ p=0.25 $$) and increased in edge brain pixels (0.80 [0.17,1.49]x10-3$$ \times 1{0}<^>{-3} $$ mm 2$$ {}<^>2 $$/s vs. 0.70 [0.18,1.48]x10-3$$ \times 1{0}<^>{-3} $$mm 2$$ {}<^>2 $$/s, p=0.02$$ p=0.02 $$) for MONO compared to Pre-ENCODE.ConclusionPre-ENCODE mitigated eddy current-induced image distortions for diffusion imaging with a shorter TE min$$ {}_{\mathrm{min}} $$ than MONO and ENCODE.
Keyword:
diffusion
eddy currents
time-optimal

期刊

Magnetic Resonance in Medicine 封面图
Magnetic Resonance in Medicine
IF:
3
论文数:
1.2W
被引数:
3.1W

机构

S
Stanford University
学者数:
9.6W
论文数: 8.2W
被引数: 17.0W
引用论文

引用论文

A novel study of the gas lift process using an integrated production/injection system using artificial neural network approach
err2020-09-14
err0
PREAI
errFarshad Abdollahi; Seyednooroldin Hosseini; Maziar Sabet; Seyyed Hamid Esmaeili-Faraj; Fatemeh Amiri
err分享
err收藏
err分享
err收藏
A bowtie model for fuel gas leakage incidents in an FPSO engine room
err2024-06-28
err0
errOAAI
errAyhan Mentes; Ertuğrul Mollaahmetoğlu; Hakan Akyildiz
err分享
err收藏
Concomitant gradient terms in phase contrast MR: Analysis and correction
err2005-12-13
err512
PREAI
errBernstein, MA; Zhou, XHJ; Polzin, JA; King, KF; Ganin, A; Pelc, NJ; Glover, GH
err分享
err收藏
Prospective and Retrospective High Order Eddy Current Mitigation for Diffusion Weighted Echo Planar Imaging
err2013-01-16
err25
PREAI
errXu, Dan; Maier, Joseph K.; King, Kevin F.; Collick, Bruce D.; Wu, Gaohong; Peters, Robert D.; Hinks, R. Scott
err分享
err收藏
Staphylococcal superantigen-like protein 13 activates neutrophils via formyl peptide receptor 2
err2018-09-17
err0
errOAAI
errYuxi Zhao; Kok P. M. van Kessel; Carla J. C. de Haas; Malbert R. C. Rogers; Jos A. G. van Strijp; Pieter-Jan A. Haas
err分享
err收藏
学者 查看更多内容