返回
Predictive digital rock physics without segmentation
DOI:10.1016/j.cageo.2021.105008.png)
摘要
En 中文
Measuring physical properties from rock samples is necessary in geosciences to calibrate models from geophysical surveys. Digital rock physics is one way to estimate these properties. X-ray computed tomography (CT) images can be used to create 3D numerical models of rocks. Numerical simulations on such models are proxies for tests performed in the lab. Commonly, segmentation is considered an essential digital rock physics processing step, where each voxel in a 3D model is assigned a property of a mineral phase or pore fluid. Any errors in this process are carried forward and affect all estimations that follow (including density, porosity, permeability, and elastic properties). The density and porosity analyses from segmentation are not predictive, as they are typically calibrated to lab tests. We explore a method that does not use segmentation and instead preserves the scaling relationship between the voxel values that are originally recorded in units of CT attenuation. The method is segmentation-less. Phantoms of known density were scanned alongside our sandstone samples and used as calibration points to convert from CT attenuation to density. A porosity model can be created as this property is negatively related to density. We use effective medium theory to assign a bulk and shear modulus to each voxel. We then experiment with several wave velocity models to estimate P and S-wave speed in order to be most similar to laboratory measurements. The ratio of our P-wave estimations to the laboratory measurements is an average of 0.98 with one effective medium theory. The density and porosity estimates do not require any external laboratory calibration. Overall, the method yields densities with an uncertainty of 44 kg/m(3) and porosities with an uncertainty of 1.67%. This method allows rock properties to be estimated quickly and accurately, on large samples, rare samples, and uniquely shaped samples that may not be the right shape for standard laboratory equipment. The technique is also less arbitrary than segmentation based digital rock physics, and is not as invasive or cumbersome as some laboratory techniques.
Keyword:
Computed tomography
Digital rock physics
Numerical modeling
Density
Porosity
Ultrasonic velocity
期刊
C
IF:
4.4
论文数:
5.0K
被引数:
1.5W
机构
引用论文
Tungsten anode spectral model using interpolating cubic splines: Unfiltered x-ray spectra from 20 kV to 640 kV
MEDICAL PHYSICS
IF3.2
An off-chip platform for on-demand, single-target encapsulation for ultrasensitive biomarker detection一种用于超灵敏生物标志物检测的片外平台,可按需进行单靶标封装
Research on Low-Cost High-Viscosity Asphalt and Its Performance for Porous Asphalt Pavement
Polymers
IF0
Coordination Chemistry of Co(II)-Bleomycin: Its Investigation through NMR and Molecular Dynamics,
Biochemistry
IF0