arrow
返回

Propeller echo-planar time-resolved imaging with dynamic encoding

delete2019-11-08
delete10
delete
OA
AI
M
Merlin J. Fair *
F
Fuyixue Wang
Z
Zijing Dong
T
Timothy G. Reese
K
Kawin Setsompop
DOI:10.1002/mrm.28071delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Purpose To develop a motion-robust extension to the recently developed echo-planar time-resolved imaging (EPTI) approach, referred to as PROPELLER EPTI with dynamic encoding (PEPTIDE), by incorporating rotations into the rapid, multishot acquisition to enable shot-to-shot motion correction. Methods Echo-planar time-resolved imaging is a multishot EPI-based approach that allows extremely rapid acquisition of distortion-free and blurring-free multicontrast imaging and quantitative mapping. By combining k-space encoding rotations into the EPTI sampling strategy to repeatedly sample the low-resolution k-space center, PEPTIDE enables significant tolerance to shot-to-shot motion and B-0 phase variations. Retrospective PEPTIDE data sets are created through a combination of in vivo EPTI data sets with rotationally acquired protocols, to enable direct comparison of the 2 methods and their robustness to identical motion. The PEPTIDE data sets are also prospectively acquired and again compared with EPTI, in the presence of true subject motion. Results The PEPTIDE approach is shown to be motion-robust to even severe subject motion (demonstrated > 30 degrees in-plane rotation, alongside translational and through-plane motion), while maintaining the rapid encoding benefits of the EPTI technique. The technique enables accurate quantitative maps to be calculated from even severe motion data sets. While the performance of the motion correction depends on the type and severity of motion encountered, in all cases PEPTIDE significantly increases image quality in the presence of motion comparative to conventional EPTI. Conclusion The newly developed PEPTIDE technique combines a high degree of motion tolerance into the EPTI framework, enabling highly rapid acquisition of distortion-free and blurring-free images at multiple TEs in the presence of motion.
Keyword:
distortion-free
EPI
EPTI
multicontrast
PROPELLER
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Magnetic Resonance in Medicine 封面图
Magnetic Resonance in Medicine
IF:
3
论文数:
1.2W
被引数:
3.1W

机构

H
Harvard University
学者数:
26.5W
论文数: 22.0W
被引数: 28.7W
引用论文

引用论文

High-resolution in vivo diffusion imaging of the human brain with generalized slice dithered enhanced resolution: Simultaneous multislice (gSlider-SMS)
err2017-03-05
err121
errOAAI
errSetsompop, Kawin; Fan, Qiuyun; Stockmann, Jason; Bilgic, Berkin; Huang, Susie; Cauley, Stephen F.; Nummenmaa, Aapo; Wang, Fuyixue; Rathi, Yogesh; Witzel, Thomas; Wald, Lawrence L.
err分享
err收藏
Real-time rigid body motion correction and shimming using cloverleaf navigators
err2006-10-06
err197
errOAAI
errvan der Kouwe, Andre J. W.; Benner, Thomas; Dale, Anders M.
err分享
err收藏
Ineffectiveness of cognitive forcing strategies to reduce biases in diagnostic reasoning: a controlled trial
errCJEM
IF0
err2015-03-04
err0
errOAAI
errJonathan Sherbino; Kulamakan Kulasegaram; Elizabeth Howey; Geoffrey Norman
err分享
err收藏
Building permanently optically active particles from an absolutely achiral polymer
err2022-01-01
err0
PREAI
errZixiang He; Tengfei Miao; Xiaoxiao Cheng; Haotian Ma; Yafei Ma; Wei Zhang; Xiulin Zhu
err分享
err收藏
Comparison of prospective head motion correction with NMR field probes and an optical tracking system
err2018-07-29
err20
errOAAI
errEschelbach, Martin; Aghaeifar, Ali; Bause, Jonas; Handwerker, Jonas; Anders, Jens; Engel, Eva-Maria; Thielscher, Axel; Scheffler, Klaus
err分享
err收藏
ECHO-PLANAR PERFUSION-SENSITIVE MR-IMAGING OF ACUTE CEREBRAL-ISCHEMIA
errRADIOLOGY
IF15.2
err1993-09-01
err132
PREAI
errKUCHARCZYK, J; VEXLER, ZS; ROBERTS, TP; ASGARI, HS; MINTOROVITCH, J; DERUGIN, N; WATSON, AD; MOSELEY, ME
err分享
err收藏
学者 查看更多内容