Quantifying photon counting detector (PCD) performance using PCD-CT images

delete2025-02-19
delete0
PRE
AI
L
Linying Zhan
G
Guang‐Hong Chen
李
李可 (Ke Li) *
DOI:10.1002/mp.17701delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
BackgroundPhoton counting detector CTs (PCD-CTs) have recently been introduced to clinical imaging. This development creates a new need for end-users to quantify and monitor the physical performance of PCDs. Traditionally, the characterization of PCD performance relied on detector counts, which are typically accessible to the manufacturer but are not usually available to clinical end-users.PurposeThe goal of this work was to develop a new method for quantifying PCD performance using reconstructed PCD-CT images, without requiring access to the PCD counts.MethodsThe proposed method is based on a set of closed-form relationships that connect PCD-CT image noise, the PCD deadtime (tau$\tau$), and the zero-frequency detective quantum efficiency (DQE0${\rm DQE}_0$) of PCDs. At a low tube current (mA) level, the mean output counts of the PCD were estimated by fitting the measured PCD-CT noise power spectrum (NPS) to a parametric model. DQE0${\rm DQE}_0$ was then calculated by normalizing the estimated mean detector counts to the expected input x-ray photon number. To estimate tau$\tau$, the image variance of PCD-CT was measured at different mA levels. A novel quantitative relationship between PCD-CT image variance, tau$\tau$, and mA was employed to estimate tau$\tau$ through parametric fitting. The method was validated using both simulated and experimental PCD-CT data, covering a range of tau$\tau$, DQE0${\rm DQE}_0$, and system geometries.ResultsFor the simulated curved-detector PCD-CT, the estimation errors for DQE0${\rm DQE}_0$ and deadtime were -3.7% and 0.5%, respectively. For the simulated collinear-detector PCD-CT, the estimation errors for DQE0${\rm DQE}_0$ and deadtime were -3.3% and -1.0%, respectively. For the experimental collinear-detector PCD-CT, the estimation errors for DQE0${\rm DQE}_0$ and deadtime were -2.6% and 1.6%, respectively.ConclusionsBy analyzing the variance and NPS of PCD-CT images, DQE0${\rm DQE}_0$ and deadtime of scanner's PCD can be accurately estimated, without access to raw detector counts or projection data.
Keyword:
CT image quality
photon counting detector
photon counting detector CT

期刊

Medical Physics 封面图
Medical Physics
IF:
3.2
论文数:
3.7W
被引数:
3.2W

机构

University of Wisconsin System 封面图
University of Wisconsin System
学者数:
6.7W
论文数: 5.8W
被引数: 382
引用论文

引用论文

First Clinical Photon-counting Detector CT System: Technical Evaluation
errRADIOLOGY
IF15.2
err2022-04-01
err308
errOAAI
errRajendran, Kishore; Petersilka, Martin; Henning, Andre; Shanblatt, Elisabeth R.; Schmidt, Bernhard; Flohr, Thomas G.; Ferrero, Andrea; Baffour, Francis; Diehn, Felix E.; Yu, Lifeng; Rajiah, Prabhakar; Fletcher, Joel G.; Leng, Shuai; McCollough, Cynthia H.
err分享
err收藏
Photon-counting x-ray detectors for CTCT用光子计数x射线探测器
err2021-01-28
err186
errOAAI
errDanielsson, Mats; Persson, Mats; Sjolin, Martin
err分享
err收藏
Cold Dialysate Regeneration System (CDRS) for Home Hemodialysis - in vivo
err2009-01-01
err0
PREAI
errJ. H. Kim; J. C. Kim; J. -H. Moon; E. Kang; C. Ronco; H. C. Kim
err分享
err收藏
Photon-Counting CT of the Brain: In Vivo Human Results and Image-Quality Assessment
err2017-10-05
err86
errOAAI
errPourmorteza, A.; Symons, R.; Reich, D. S.; Bagheri, M.; Cork, T. E.; Kappler, S.; Ulzheimer, S.; Bluemke, D. A.
err分享
err收藏
Performance evaluation of single- and dual-contrast spectral imaging on a photon-counting-detector CT在光子计数探测器CT上进行单对比和双对比光谱成像的性能评估
err2024-09-05
err2
PREAI
errRen, Liqiang; Zhou, Zhongxing; Ahmed, Zaki; Rajendran, Kishore; Fletcher, Joel G.; McCollough, Cynthia H.; Yu, Lifeng
err分享
err收藏
学者 查看更多内容