摘要

En 中文
This paper proposes a re-entrant optical fiber current sensor based on continuous light, which achieves continuous measurement while improving current measurement sensitivity. Based on the traditional re-entry structure, the sensor employs continuous light measurement, where the current signal manifests as a phase difference between two circularly polarized lights caused by the Faraday effect. This phase difference results in an interference pattern reflected in the light intensity changes. The final measured signal is the cumulative interference signal light intensity of different cycles, demodulated using the phase-generated carrier technology. Experimental results demonstrate that the sensitivity of the structure is 1.8 times that of the traditional reflective structure under the same configuration, and the current measurement accuracy is 0.8 mA. The sensitivity can be further improved by reducing the losses within the resonant cavity. This scheme offers a new approach for the low-cost application of re-entrant structures in the field of current measurement.
Keyword:
Optical fibers
Optical fiber sensors
Sensitivity
Optical polarization
Current measurement
Optical reflection
Optical fiber polarization
Fiber optic current sensor
phase-generated carrier demodulation
re-entrant structure
sensitivity enhancement
tunable current sensitivity

期刊

Journal of Lightwave Technology 封面图
Journal of Lightwave Technology
IF:
4.8
论文数:
1.7W
被引数:
3.8W

机构

暂无机构信息
引用论文

引用论文

Compact Tb doped fiber optic current sensor with high sensitivity
err2015-11-06
err41
errOAAI
errHuang, Duanni; Srinivasan, Sudharsanan; Bowers, John E.
err分享
err收藏
A Huge Hemorrhagic Epidermoid Cyst of the Perineum with Hypoechoic Semisolid Ultrasonographic Feature Mimicking Scar Endometriosis
err2021-03-17
err0
errOAAI
errGina Nam; Sa Ra Lee; Hye Rim Eum; Sung Hoon Kim; Hee Dong Chae; Gwang Jun Kim
err分享
err收藏
In-line sagnac interferometer current sensor
err1996-01-01
err256
PREAI
errBlake, J; Tantaswadi, P; deCarvalho, RT
err分享
err收藏
Sensitivity-improved fiber optic current sensor based on an optoelectronic oscillator utilizing a dispersion induced microwave photonic filter
err2021-11-08
err9
errOAAI
errZhang, Naihan; Wang, Muguang; Wu, Beilei; Han, Mengyao; Zhang, Jing; Liu, Yan; Fan, Guofang
err分享
err收藏
err分享
err收藏
学者 查看更多内容