arrow
返回

Reducing image artifacts in sparse projection CT using conditional generative adversarial networks

delete2024-02-16
delete2
delete
OA
AI
K
Keisuke Usui *
S
Sae Kamiyama
A
Akihiro Arita
K
K. Ogawa
H
Hajime Sakamoto
Y
Yasuaki Sakano
S
Shinsuke Kyogoku
H
Hiroyuki Daida
DOI:10.1038/s41598-024-54649-xdelete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Reducing the amount of projection data in computed tomography (CT), specifically sparse-view CT, can reduce exposure dose; however, image artifacts can occur. We quantitatively evaluated the effects of conditional generative adversarial networks (CGAN) on image quality restoration for sparse-view CT using simulated sparse projection images and compared them with autoencoder (AE) and U-Net models. The AE, U-Net, and CGAN models were trained using pairs of artifacts and original images; 90% of patient cases were used for training and the remaining for evaluation. Restoration of CT values was evaluated using mean error (ME) and mean absolute error (MAE). The image quality was evaluated using structural image similarity (SSIM) and peak signal-to-noise ratio (PSNR). Image quality improved in all sparse projection data; however, slight deformation in tumor and spine regions was observed, with a dispersed projection of over 5 degrees. Some hallucination regions were observed in the CGAN results. Image resolution decreased, and blurring occurred in AE and U-Net; therefore, large deviations in ME and MAE were observed in lung and air regions, and the SSIM and PSNR results were degraded. The CGAN model achieved accurate CT value restoration and improved SSIM and PSNR compared to AE and U-Net models.
Keyword:
Sparse projection
CGAN
Deep learning
Artifact reduction
CT
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Scientific Reports 封面图
Scientific Reports
IF:
3.9
论文数:
27.9W
被引数:
83.5W

机构

H
Hosei University
学者数:
953
论文数: 1.1K
被引数: 718
J
Juntendo University
学者数:
1.0W
论文数: 7.4K
被引数: 6.5K
引用论文

引用论文

Trp-dependent auxin biosynthesis in Arabidopsis: involvement of cytochrome P450s CYP79B2 and CYP79B3
err2002-12-01
err0
errOAAI
errYunde Zhao; Anna K. Hull; Neeru R. Gupta; Kendrick A. Goss; José Alonso; Joseph R. Ecker; Jennifer Normanly; Joanne Chory; John L. Celenza
err分享
err收藏
Sparse-view x-ray CT reconstruction via total generalized variation regularization
err2014-05-19
err235
errOAAI
errNiu, Shanzhou; Gao, Yang; Bian, Zhaoying; Huang, Jing; Chen, Wufan; Yu, Gaohang; Liang, Zhengrong; Ma, Jianhua
err分享
err收藏
学者 查看更多内容