Figure measuring interferometers generally work in the null condition, i.e., the reference rays share the same optical path with the test rays through the imaging system. In this case, except field distortion error, effect of other aberrations cancels out and doesn't result in measureable systematic error. However, for spatial carrier interferometry and non-null aspheric test cases, null condition cannot be achieved typically, and there is excessive measurement error that is referenced as retrace error. Previous studies about retrace error can be generally distinguished into two categories: one based on 4th-order aberration formalism, the other based on ray tracing through interferometer model. In this paper, point characteristic function (PCF) is used to analyze retrace error in a Fizeau interferometer working in high spatial carrier condition. We present the process of reconstructing retrace error with and without element error in detail. Our results are in contrast with those obtained by ray tracing through interferometer model. The small difference between them (less than 3%) shows that our method is effective. (C) 2015 Optical Society of America
Keyword:
INTERFEROMETRY
CALIBRATION
SURFACES
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Optics Express 封面图
Optics Express
IF:
3.3
论文数:
6.1W
被引数:
14.3W

机构

C
chinese academy of sciences
学者数:
56.7W
论文数: 45.0W
被引数: 704
引用论文

引用论文

err
IF0
err
err0
PREAI
err
err分享
err收藏
err
IF0
err
err0
PREAI
err
err分享
err收藏
Comparing Outcomes of Phacoemulsification and Endocyclophotocoagulation with Either Dual Blade Goniotomy (PEcK) or Two Trabecular Stents (ICE2)
err2023-10-01
err0
errOAAI
errHani El Helwe; Blake Oberfeld; Fatemeh Golsoorat Pahlaviani; Henisk Falah; Jonathan Trzcinski; David Solá-Del Valle
err分享
err收藏
Practical methods for retrace error correction in nonnull aspheric testing
err2009-04-13
err73
errOAAI
errLiu, Dong; Yang, Yongying; Tian, Chao; Luo, Yongjie; Wang, Lin
err分享
err收藏
Calibration of a non-null test interferometer for the measurement of aspheres and free-form surfaces
err2014-12-10
err73
errOAAI
errBaer, Goran; Schindler, Johannes; Pruss, Christof; Siepmann, Jens; Osten, Wolfgang
err分享
err收藏
Chromatin
err2001-01-01
err0
PREAI
errJ.Y. Lee; T.L. Orr-Weaver
err分享
err收藏
没有更多内容