Revised Motion Estimation Algorithm for PROPELLER MRI

delete2013-09-04
delete35
delete
OA
AI
J
James G. Pipe *
W
Wende N. Gibbs
Z
Zhiqiang Li
J
John P. Karis
M
Michael Schär
N
Nicholas R. Zwart
DOI:10.1002/mrm.24929delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Purpose: To introduce a new algorithm for estimating data shifts (used for both rotation and translation estimates) for motion-corrected PROPELLER MRI. The method estimates shifts for all blades jointly, emphasizing blade-pair correlations that are both strong and more robust to noise. Theory and Methods: The heads of three volunteers were scanned using a PROPELLER acquisition while they exhibited various amounts of motion. All data were reconstructed twice, using motion estimates from the original and new algorithm. Two radiologists independently and blindly compared 216 image pairs from these scans, ranking the left image as substantially better or worse than, slightly better or worse than, or equivalent to the right image. Results: In the aggregate of 432 scores, the new method was judged substantially better than the old method 11 times, and was never judged substantially worse. Conclusion: The new algorithm compared favorably with the old in its ability to estimate bulk motion in a limited study of volunteer motion. A larger study of patients is planned for future work. (C) 2013 Wiley Periodicals, Inc.
Keyword:
MRI
motion
PROPELLER
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

err分享
err收藏
err分享
err收藏
T1 weighted fat/water separated PROPELLER acquired with dual bandwidths
err2018-04-24
err8
PREAI
errRyden, Henric; Berglund, Johan; Norbeck, Ola; Avventi, Enrico; Skare, Stefan
err分享
err收藏
MRI of the lung using the PROPELLER technique: Artifact reduction, better image quality and improved nodule detection
err2016-04-01
err36
PREAI
errMeier-Schroers, Michael; Kukuk, Guido; Homsi, Rami; Skowasch, Dirk; Schild, Hans Heinz; Thomas, Daniel
err分享
err收藏
AI-based motion artifact severity estimation in undersampled MRI allowing for selection of appropriate reconstruction models
err2024-01-03
err2
errOAAI
errBeljaards, Laurens; Pezzotti, Nicola; Rao, Chinmay; Doneva, Mariya; van Osch, Matthias J. P.; Staring, Marius
err分享
err收藏
An MRI-Compatible Platform for One-Dimensional Motion Management Studies in MRIMRI兼容平台,用于MRI中的一维运动管理研究
err2015-10-23
err4
errOAAI
errNofiele, Joris; Yuan, Qing; Kazem, Mohammad; Tatebe, Ken; Torres, Quinn; Sawant, Amit; Pedrosa, Ivan; Chopra, Rajiv
err分享
err收藏

期刊

Magnetic Resonance in Medicine 封面图
Magnetic Resonance in Medicine
IF:
3
论文数:
1.2W
被引数:
3.8W

机构

P
philips
学者数:
58
论文数: 35
被引数: 1.5K
B
Barrow Neurological Institute
学者数:
101
论文数: 59
被引数: 856
引用论文

引用论文

Improved motion correction capabilities for fast spin echo T1 FLAIR propeller using non-Cartesian external calibration data driven parallel imaging
err2012-03-02
err15
errOAAI
errHolmes, James H.; Beatty, Philip J.; Rowley, Howard A.; Li, Zhiqiang; Gaddipati, Ajeetkumar; Zhao, Xiaoli; Busse, Reed F.; Brittain, Jean H.
err分享
err收藏
Rapid PROPELLER-MRI: A combination of iterative reconstruction and under-sampling
err2012-06-11
err5
errOAAI
errTamhane, Ashish A.; Arfanakis, Konstantinos; Anastasio, Mark; Guo, Xiaodong; Vannier, Michael; Gao, Jia-Hong
err分享
err收藏
Efficient sample density estimation by combining gridding and an optimized kernel
err2011-06-17
err88
errOAAI
errZwart, Nicholas R.; Johnson, Kenneth O.; Pipe, James G.
err分享
err收藏
没有更多内容