arrow
返回

Sample dispersion for segmented flow in microchannels with rectangular cross section

delete2008-01-30
delete63
PRE
AI
M
Michiel T. Kreutzer
A
Axel Günther
K
Klavs F. Jensen *
DOI:10.1021/ac702143rdelete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Hydrodynamic dispersion in microchannels can be significantly reduced by segmentation with a second immiscible phase. We address the effect of microchannel cross section on the dispersion of analytes in a segmented gas-liquid flow of alternating bubbles and liquid segments. Channels of square or nearly square cross section are considered. A significant fraction of the liquid surrounds the bubbles and wets the channel walls in the form of films or menisci. This stagnant fraction of the liquid remains when gas and liquid segments flow by, and it is connected to the liquid within the liquid segments by diffusion only and it effectively increases dispersion. We design and fabricate a microchip with integrated analyte injection and detection to investigate the effects of the influence of the stagnant liquid in segmented flow through square microchannels on the analyte bandwidth. The measured data and a corresponding model confirm the experimental trends and suggest operating conditions at which the unwanted effect of dispersion in segmented microchannel flow is minimized. Dispersion is least when the liquid flow rate is greater than the gas flow rate, and the optimum ratio of the two flow rates slightly increases with increasing bubble velocity.
Keyword:
RESIDENCE TIME DISTRIBUTION
MULTIPHASE MONOLITH REACTORS
GAS-LIQUID FLOW
MICROFLUIDIC SYSTEMS
MASS-TRANSFER
ASPECT RATIO
TAYLOR FLOW
CHANNELS
BUBBLES
MOTION
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Analytical Chemistry 封面图
Analytical Chemistry
IF:
6.7
论文数:
4.7W
被引数:
15.9W

机构

暂无机构信息
引用论文

引用论文

Separation of flavonoids by reversed-phase high-performance liquid chromatography
err1982-05-01
err0
PREAI
errKarel Vande Casteele; Hans Geiger; Christiaan F. Van Sumere
err分享
err收藏
Diffusion coefficient measurements in microfluidic devices
errTALANTA
IF6.1
err2002-02-11
err443
PREAI
errCulbertson, CT; Jacobson, SC; Ramsey, JM
err分享
err收藏
Value of nocturnal oxygen saturation as a screening test for sleep apnoea.
err1991-08-01
err0
errOAAI
errB G Cooper; D Veale; C J Griffiths; G J Gibson
err分享
err收藏
err分享
err收藏
Information Flow Between Resting-State Networks
err2015-11-01
err0
errOAAI
errIbai Diez; Asier Erramuzpe; Iñaki Escudero; Beatriz Mateos; Alberto Cabrera; Daniele Marinazzo; Ernesto J. Sanz-Arigita; Sebastiano Stramaglia; Jesus M. Cortes Diaz
err分享
err收藏
学者 查看更多内容