arrow
返回

Second-order universal calibration

delete2020-05-01
delete2
PRE
AI
M
Mahdiyeh Ghaffari
M
Mohammad Reza Khoshayand
L
Ludovic Duponchel
H
Hamid Abdollahi *
DOI:10.1016/j.talanta.2020.120787delete
delete原文链接
delete分享
delete收藏
摘要

摘要

En 中文
Quantification and qualification of an analyte of interest in pharmaceutical tablets from different manufacturers/companies are a hard task because of the potential presence of various interfering molecules. Indeed, the composition of the tablets covers a wide range of interferents which can be even unknown. As a consequence, we propose to determine the concentration of an analyte of interest regardless of the interferents using the concept of universal calibration. Universal calibration paves the way to the quantification of a specific chemical entity in samples with various compositions and different interferents. This is possible by the trilinear structure of ana: lyte's signal. In fact, the second-order advantage resulting from the second-order universal calibration models is exploited. However, a new second-order calibration strategy was conducted in this work using Trilinear Factor Extraction (TFE). A simulated data set was exemplified to highlight the ability of the proposed procedure in order to accurate extraction of the analytes concentration profile. Additionally, two real data sets were also explored in order to test the TFE method. In the first case, Acetaminophen was quantified using fluorescence spectroscopy in tablets with different formulations from 6 companies. In the second experimental data, a peptide (Valine-Tyrosine-Valine) was successfully quantified in different samples using spectrofluorimetric data. Finally, these real data sets were analyzed by Multivariate Curve resolution - Alternating Least-Squares (MCR-ALS) under non-negativity and trilinearity constraints for the sake of comparison. The calculated Root Mean Square Error of Predictions (RMSEP) of Acetaminophen were 0.028 and 0.026 for the MCR-ALS and TFE models, respectively. On the other hand, for the second experimental data set, the RMSEP were 0.216 and 0.165, respectively. Finally, based on a paired t-test, the results of MCR-ALS and TFE were not significantly different.
Keyword:
Universal calibration
Trilinear factor extraction
Quantitative analysis
Second order calibration
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Talanta 封面图
Talanta
IF:
6.1
论文数:
2.6W
被引数:
8.2W

机构

U
Université de Lille
学者数:
314
论文数: 147
被引数: 1.2W
T
Tehran University of Medical Sciences
学者数:
1.2K
论文数: 418
被引数: 9.5K
引用论文

引用论文

err分享
err收藏
Raman chemical imaging for spectroscopic screening and direct quantification of falsified drugs
err2018-01-01
err40
PREAI
errRebiere, Herve; Martin, Maxime; Ghyselinck, Celine; Bonnet, Pierre-Antoine; Brenier, Charlotte
err分享
err收藏
Enhanced Extraction of Phenobarbital from Serum with a Designed Artificial Receptor
err2002-05-01
err0
PREAI
errJane N. Valenta; Robert P. Dixon; Andrew D. Hamilton; Stephen G. Weber
err分享
err收藏
err分享
err收藏
学者 查看更多内容