arrow
返回

Sensing changes in triglyceride concentration in blood solution using diffuse optical spectroscopy

delete2026-01-19
delete0
PRE
AI
梁思奇 封面图
梁思奇 (Siqi Liang)
N
Nan Wan
G
Guo Chen
S
Sung‐Liang Chen *
M
Myeongsu Seong *
DOI:10.1016/j.optlastec.2026.114767delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Triglyceride (TG) is a fundamental lipid component in the bloodstream. While TG is fundamental in the body, elevated TG levels, exceeding 150 mg/dL, pose a heightened risk for multiple diseases, notably cardiovascular disease. Monitoring TG concentration is imperative to assess the efficacy of interventions aimed at lowering the TG concentration and diagnosing hypertriglyceridemia (HTG, TG concentration ≥ 200 mg/dL). Although various techniques exist for TG concentration monitoring, conventional techniques often require sample collection and/or sample preprocessing or lack portability. Recognizing the importance of TG concentration monitoring, this work endeavors to explore the viability of diffuse optical monitoring of TG concentration variations in blood. To validate the feasibility, a series of Monte Carlo simulations was performed. Then, samples containing flowing mixtures of varying TG concentrations and hemoglobin solution (for phantom experiments) or sheep blood (for ex vivo experiments) were measured using continuous-wave diffuse optical spectroscopy (CW-DOS) to experimentally demonstrate the capability of diffuse optical monitoring of TG concentration variations. Our results showed a linear decrease in CW-DOS amplitude at 885 nm with increasing TG concentration up to 800 mg/dL. In addition, in vivo mouse studies were conducted, including a control group receiving saline (n = 5) and a test group administered triton WR-1339 (n = 5), to further demonstrate the applicability of the technique. Our results suggest that CW-DOS holds promise as a noninvasive and longitudinal tool for monitoring TG concentration, facilitating the diagnosis of HTG and the assessment of the efficacy of interventions aimed at reducing TG levels in individuals.

期刊

O
optics & laser technology
IF:
0
论文数:
880
被引数:
0

机构

H
Hunan University of Science and Technology
学者数:
1.3K
论文数: 578
被引数: 5.5K
X
Xian Jiaotong Liverpool University
学者数:
202
论文数: 93
被引数: 0
S
Shanghai Jiao Tong University
学者数:
7.8K
论文数: 2.4K
被引数: 14.8W
学者 查看更多机构
引用论文

引用论文

Hematological and biochemical reference values for C57BL/6, Swiss Webster and BALB/c mice
err2016-06-17
err0
errOAAI
errEd Wilson Santos; Dalila Cunha de Oliveira; Araceli Hastreiter; Graziela Batista da Silva; Jackeline Soares de Oliveira Beltran; Maristela Tsujita; Amanda Rabelo Crisma; Silvânia Meiry Peris Neves; Ricardo Ambrósio Fock; Primavera Borelli
err分享
err收藏
Within-subject and between-subject biological variation estimates of 21 hematological parameters in 30 healthy subjects
err2018-07-26
err0
errOAAI
errAbdurrahman Coşkun; Anna Carobene; Meltem Kilercik; Mustafa Serteser; Sverre Sandberg; Aasne K. Aarsand; Pilar Fernandez-Calle; Niels Jonker; William A. Bartlett; Jorge Díaz-Garzón; Sibel Huet; Cansu Kızıltaş; Ilayda Dalgakıran; Esra Ugur; Ibrahim Unsal
err分享
err收藏
Light scattering in lntralipid-10% in the wavelength range of 400–1100 nm
err1991-11-01
err0
PREAI
errHugo J. van Staveren; Christian J. M. Moes; Jan van Marie; Scott A. Prahl; Martin J. C. van Gemert
err分享
err收藏
Shortwave-infrared meso-patterned imaging enables label-free mapping of tissue water and lipid content短波红外中图案成像可实现组织水和脂质含量的无标记映射
err2020-10-23
err52
errOAAI
errZhao, Yanyu; Pilvar, Anahita; Tank, Anup; Peterson, Hannah; Jiang, John; Aster, Jon C.; Dumas, John Paul; Pierce, Mark C.; Roblyer, Darren
err分享
err收藏
err分享
err收藏
学者 查看更多内容