Currently, CT scanning is often performed using flat detectors which are mounted on C-arm units or dedicated gantries as in radiation therapy or micro CT. For perspective cone-beam backprojection of the Feldkamp type (FDK) the geometry of an approximately circular scan trajectory has to be available for reconstruction. If the system or the scan geometry is afflicted with geometrical instabilities, referred to as misalignment, a non-perfect approximate circular scan is the case. Reconstructing a misaligned scan without knowledge of the true trajectory results in severe artefacts in the CT images. Unlike current methods which use a pre-scan calibration of the geometry for defined scan protocols and calibration phantoms, we propose a real-time iterative restoration of reconstruction geometry by means of entropy minimization. Entropy minimization is performed combining a simplex algorithm for multi- parameter optimization and iterative graphics card (GPU)-based FDK-reconstructions. Images reconstructed with the misaligned geometry were used as an input for the entropy minimization algorithm. A simplex algorithm changes the geometrical parameters of the source and detector with respect to the reduction of entropy. In order to reduce the size of the high-dimensional space required forminimization, the trajectory was described by only eight fix points. Avirtual trajectory is generated for each iteration using a least-mean-squares algorithm to calculate an approximately circular path including these points. Entropy was minimal for the ideal dataset, whereas strong misalignment resulted in a higher entropy value. For the datasets used in this study, the simplex algorithm required 64 - 200 iterations to achieve an entropy value equivalent to the ideal dataset, depending on the grade of misalignment using random initialization conditions. The use of the GPU reduced the time per iteration as compared to a quad core CPU-based backprojection by a factor of 10 resulting in a total of 15-20 ms per iteration, and thus providing an online geometry restoration after a total computation time of approximately 1-3 s, depending on the number of iterations. The proposed method provides accurate geometry restoration for approximately circular scans and eliminates the need for an elaborate off-line calibration for each scan. If a priori information about the trajectory is used to initialize the simplex algorithm, it is expected that the entropy minimization will converge significantly faster.
Keyword:
ARM MOUNTED XRII
C-ARM
GEOMETRICAL CALIBRATION
SIMPLEX-METHOD
RECONSTRUCTION
ALGORITHM
SYSTEM
PARAMETERS
DETECTOR
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Physics in Medicine and Biology 封面图
Physics in Medicine and Biology
IF:
3.4
论文数:
1.4W
被引数:
3.1W

机构

U
University of Erlangen Nuremberg
学者数:
3.2W
论文数: 2.6W
被引数: 29
引用论文

引用论文

The stability of mechanical calibration for a kV cone beam computed tomography system integrated with linear accelerator
err2005-12-23
err141
PREAI
errSharpe, MB; Moseley, DJ; Purdie, TG; Islam, M; Siewerdsen, JH; Jaffray, DA
err分享
err收藏
err分享
err收藏
Enhanced 3-D-reconstruction algorithm for C-arm systems suitable for interventional procedures
err2000-05-01
err201
PREAI
errWiesent, K; Barth, K; Navab, N; Durlak, P; Brunner, T; Schuetz, O; Seissler, W
err分享
err收藏
err分享
err收藏
学者 查看更多内容