Single-test Ritchey-Common interferometry

delete2023-12-18
delete0
delete
OA
AI
Y
Yiming Liu
C
Chuheng Xu
Y
Yao Hu *
H
Huiqin Lu
J
Jinpeng Li
T
Tiancheng Wu
张少辉 (Shaohui Zhang)
C
Chang Xu
Q
Qun Hao
DOI:10.1364/OE.505632delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
The Ritchey-Common test is widely adopted to measure large optical flats. The traditional Ritchey-Common test eliminates the defocus error with multiple tests by changing the position of the mirrors, which suffers from cumbersome steps, poor repeatability, coupled system error, extra mirror deformation, and potential overturning. The above problems increase the test time, decrease the reliability and accuracy, increase the test cost, and threaten manufacturing safety. We propose a single-test Ritchey-Common interferometry to avoid the obligatory position change in the traditional method. A sub-aperture of test flat is directly measured by a small-aperture interferometer before the test, which is easy to implement, to replace the extra system wavefront measurement in different positions. The defocus is calculated in sub-aperture at exactly the same position as the full-field measurement without the position change, then the surface form under test can be obtained with accurate optical path modeling. Measurement experiments for 100 mm and 2050 mm aperture flats were performed to demonstrate the feasibility of this method. Compared with a direct test in a standard Zygo interferometer, the peak to valley (PV) and root mean square (RMS) errors were 0.0889 ? and 0.0126 ? (?=632.8 nm), respectively, which reaches the upper limit of accuracy of the interferometer. To the best of our knowledge, this is the first proposal of the Ritchey-Common test that can eliminate the defocus error and realize high accuracy measurement in a single test. Our work paves the way for reliable and practical optical metrology for large optical flats.
Keyword:
LARGE OPTICS
TELESCOPE

期刊

Optics Express 封面图
Optics Express
IF:
3.3
论文数:
6.1W
被引数:
14.3W

机构

B
beijing institute of technology
学者数:
5.5W
论文数: 4.0W
被引数: 63
C
chinese academy of sciences
学者数:
56.7W
论文数: 45.0W
被引数: 704
引用论文

引用论文

LONGITUDINAL CHANGES IN CHOROIDAL AND RETINAL THICKNESSES IN CHILDREN WITH MYOPIC SHIFT
err2019-06-01
err0
errOAAI
errPeiyao Jin; Haidong Zou; Xun Xu; Ta Chen Chang; Jianfeng Zhu; Junjie Deng; Minzhi Lv; Jiali Jin; Sifei Sun; Ling Wang; Xiangui He
err分享
err收藏
An Isolable Phosphaethynolatoborane and Its Reactivity
err2018-01-25
err0
PREAI
errDaniel W. N. Wilson; Alexander Hinz; Jose M. Goicoechea
err分享
err收藏
Temporary facial nerve dysfunction after parotidectomy correlates with tumor location
err2014-10-01
err0
PREAI
errRyo Ikoma; Junichi Ishitoya; Yasunori Sakuma; Mariko Hirama; Osamu Shiono; Masanori Komatsu; Nobuhiko Oridate
err分享
err收藏
Subaperture stitching test of large steep convex spheres
err2015-10-29
err29
errOAAI
errChen, Shanyong; Xue, Shuai; Dai, Yifan; Li, Shengyi
err分享
err收藏
Management of parotid gland surgery in a university teaching hospital
err2009-09-18
err0
PREAI
errSophie Deneuve; Stephanie Quesnel; Joel Depondt; Sebastien Albert; Alexandra Panajotopoulos; Pierre Gehanno; Beatrix Barry
err分享
err收藏
Virtual-real combination Ritchey-Common interferometry
err2022-04-22
err9
errOAAI
errLiu, Yiming; Hu, Yao; Zhang, Shaohui; Huang, Shen; Li, Jinpeng; Yan, Limin; Lv, Jiahang; Wang, Zhen; Chang, Xu; Hao, Qun
err分享
err收藏
Pediatric Septic Arthritis
err1997-07-01
err0
PREAI
errAnthony J Matan; John T Smith
err分享
err收藏
学者 查看更多内容