arrow
返回

Slice-level diffusion encoding for motion and distortion correction

delete2018-08-01
delete20
delete
OA
AI
J
Jana Hutter *
D
Daan Christiaens
T
Torben Schneider
C
Cordero-Grande, Lucilio
P
Paddy J. Slator
M
Maria Deprez
A
Anthony N. Price
J
Jacques‐Donald Tournier
M
Mary Rutherford
J
Joseph V. Hajnal
DOI:10.1016/j.media.2018.06.008delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Advances in microstructural modelling are leading to growing requirements on diffusion MRI acquisitions, namely sensitivity to smaller structures and better resolution of the geometric orientations. The resulting acquisitions contain highly attenuated images that present particular challenges when there is motion and geometric distortion. This study proposes to address these challenges by breaking with the conventional one-volume-one-encoding paradigm employed in conventional diffusion imaging using single-shot Echo Planar Imaging. By enabling free choice of the diffusion encoding on the slice level, a higher temporal sampling of slices with low b-value can be achieved. These allow more robust motion correction, and in combination with a second reversed phase-encoded echo, also dynamic distortion correction. These proposed advances are validated on phantom and adult experiments and employed in a study of eight foetal subjects. Equivalence in obtained diffusion quantities with the conventional method is demonstrated as well as benefits in distortion and motion correction. The resulting capability can be combined with any acquisition parameters including multiband imaging and allows application to diffusion MRI studies in general. (C) 2018 The Authors. Published by Elsevier B.V.
Keyword:
MRI
Diffusion
Motion correction
Microstructure
Foetal imaging
EPI

期刊

Medical Image Analysis 封面图
Medical Image Analysis
IF:
11.8
论文数:
3.9K
被引数:
2.4W

机构

P
Philips
学者数:
4.0K
论文数: 3.4K
被引数: 1
U
university of london
学者数:
21.5W
论文数: 19.7W
被引数: 305
引用论文

引用论文

AxCaliber: A method for measuring axon diameter distribution from diffusion MRI
err2008-05-27
err729
errOAAI
errAssaf, Yaniv; Blumenfeld-Katzir, Tamar; Yovel, Yossi; Basser, Peter J.
err分享
err收藏
Interaction of hemoglobin with chloride and 2,3‐bisphosphoglycerate
err2005-03-03
err0
errOAAI
errBruno GIARDINA; Ole BRIX; Alfredo COLOSIMO; Raffaele PETRUZZELLI; Loredana CERRONI; Saverio G. CONDO
err分享
err收藏
Real-Time Optical Motion Correction for Diffusion Tensor Imaging扩散张量成像的实时光学运动校正
err2011-03-22
err117
errOAAI
errAksoy, Murat; Forman, Christoph; Straka, Matus; Skare, Stefan; Holdsworth, Samantha; Hornegger, Joachim; Bammer, Roland
err分享
err收藏
Simultaneous Multislice (SMS) Imaging Techniques
err2015-08-26
err481
errOAAI
errBarth, Markus; Breuer, Felix; Koopmans, Peter J.; Norris, David G.; Poser, Benedikt A.
err分享
err收藏
err分享
err收藏
err分享
err收藏
Lymphoid-Restricted Development From Multipotent Candidate Murine Stem Cells: Distinct and Complimentary Functions of the c-kit and flt3-Ligands
err1999-12-01
err0
PREAI
errOle Johan Borge; Jörgen Adolfsson; Annica Mårtensson, Inga-Lill Mårtensson, and Sten E.W. Jacobsen
err分享
err收藏
学者 查看更多内容